{"resultsPerPage":13,"startIndex":0,"totalResults":13,"format":"NVD_CVE","version":"2.0","timestamp":"2026-11-05T02:08:18.908","vulnerabilities":[{"cve":{"id":"CVE-2017-14797","sourceIdentifier":"cve@mitre.org","published":"2017-10-01T01:29:00.723","lastModified":"2026-06-17T01:06:46.730","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"Lack of Transport Encryption in the public API in Philips Hue Bridge BSB002 SW 1707040932 allows remote attackers to read API keys (and consequently bypass the pushlink protection mechanism, and obtain complete control of the connected accessories) by leveraging the ability to sniff HTTP traffic on the local intranet network."},{"lang":"es","value":"La ausencia de cifrado en la capa de transporte en la API publica en Philips Hue Bridge BSB002 SW 1707040932 permite que los atacantes remotos lean claves de API (y en consecuencia omitir el mecanismo de protección pushlink y obtener el control completo de los accesorios conectados) mediante la capacidad para rastrear el tráfico HTTP en la intranet local."}],"affected":[{"source":"cve@mitre.org","affectedData":[{"vendor":"n/a","product":"n/a","versions":[{"version":"n/a","status":"affected"}]}]}],"metrics":{"cvssMetricV30":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":7.5,"baseSeverity":"HIGH","attackVector":"ADJACENT_NETWORK","attackComplexity":"HIGH","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.6,"impactScore":5.9}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:A/AC:M/Au:N/C:C/I:C/A:C","baseScore":7.9,"accessVector":"ADJACENT_NETWORK","accessComplexity":"MEDIUM","authentication":"NONE","confidentialityImpact":"COMPLETE","integrityImpact":"COMPLETE","availabilityImpact":"COMPLETE"},"baseSeverity":"HIGH","exploitabilityScore":5.5,"impactScore":10.0,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-326"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:philips:hue_bridge_bsb002_firmware:1707040932:*:*:*:*:*:*:*","matchCriteriaId":"32D4FB5F-8B57-436B-991C-F300A9B09B40"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:philips:hue_bridge_bsb002:-:*:*:*:*:*:*:*","matchCriteriaId":"1A54ECAB-98FB-4E50-B359-C01FB23FE3FC"}]}]}],"references":[{"url":"https://www.tiferrei.com/philips-we-need-to-talk","source":"cve@mitre.org"},{"url":"https://www.tiferrei.com/philips-we-need-to-talk","source":"af854a3a-2127-422b-91ae-364da2661108"}]}},{"cve":{"id":"CVE-2020-6007","sourceIdentifier":"cve@checkpoint.com","published":"2020-01-23T22:15:10.277","lastModified":"2026-06-17T03:22:34.960","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"Philips Hue Bridge model 2.X prior to and including version 1935144020 contains a Heap-based Buffer Overflow when handling a long ZCL string during the commissioning phase, resulting in a remote code execution."},{"lang":"es","value":"Philips Hue Bridge modelo 2.X versiones anteriores a 1935144020 incluyéndola, contiene un desbordamiento de búfer en la región heap de la memoria cuando se maneja una cadena ZCL larga durante la fase de comisionamiento, resultando en una ejecución de código remota."}],"affected":[{"source":"cve@checkpoint.com","affectedData":[{"vendor":"n/a","product":"Philips Hue Bridge 2.X","versions":[{"version":"All versions prior to and including 1935144020","status":"affected"}]}]}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H","baseScore":7.9,"baseSeverity":"HIGH","attackVector":"ADJACENT_NETWORK","attackComplexity":"HIGH","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"CHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.2,"impactScore":6.0}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:A/AC:H/Au:N/C:P/I:P/A:P","baseScore":4.3,"accessVector":"ADJACENT_NETWORK","accessComplexity":"HIGH","authentication":"NONE","confidentialityImpact":"PARTIAL","integrityImpact":"PARTIAL","availabilityImpact":"PARTIAL"},"baseSeverity":"MEDIUM","exploitabilityScore":3.2,"impactScore":6.4,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":true}]},"weaknesses":[{"source":"cve@checkpoint.com","type":"Secondary","description":[{"lang":"en","value":"CWE-122"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-787"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:philips:hue_bridge_v2_firmware:*:*:*:*:*:*:*:*","versionEndIncluding":"1935144020","matchCriteriaId":"E33656C1-57BE-4579-8212-B8AE6E57DF08"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:philips:hue_bridge_v2:-:*:*:*:*:*:*:*","matchCriteriaId":"55B37D18-3A59-423E-9D73-F80DFDB14C4D"}]}]}],"references":[{"url":"https://research.checkpoint.com/2020/dont-be-silly-its-only-a-lightbulb/","source":"cve@checkpoint.com","tags":["Exploit","Third Party Advisory"]},{"url":"https://www2.meethue.com/en-us/support/release-notes/bridge","source":"cve@checkpoint.com","tags":["Product","Release Notes"]},{"url":"https://research.checkpoint.com/2020/dont-be-silly-its-only-a-lightbulb/","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Exploit","Third Party Advisory"]},{"url":"https://www2.meethue.com/en-us/support/release-notes/bridge","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Product","Release Notes"]}]}},{"cve":{"id":"CVE-2018-7580","sourceIdentifier":"cve@mitre.org","published":"2020-12-21T21:15:12.603","lastModified":"2026-06-17T02:03:24.550","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"Philips Hue is vulnerable to a Denial of Service attack. Sending a SYN flood on port tcp/80 will freeze Philips Hue's hub and it will stop responding. The \"hub\" will stop operating and be frozen until the flood stops. During the flood, the user won't be able to turn on/off the lights, and all of the hub's functionality will be unresponsive. The cloud service also won't work with the hub."},{"lang":"es","value":"Philips Hue es vulnerable a un ataque de Denegación de Servicio.&#xa0;El envío de una inundación de SYN en el puerto tcp/80 congelará el concentrador de Philips Hue y dejará de responder.&#xa0;El \"hub\" dejará de funcionar y se congelará hasta que se detenga la inundación.&#xa0;Durante la inundación, el usuario no podrá encender y apagar las luces y todas las funciones del hub dejarán de responder.&#xa0;El servicio en la nube tampoco funcionará con el concentrador"}],"affected":[{"source":"cve@mitre.org","affectedData":[{"vendor":"n/a","product":"n/a","versions":[{"version":"n/a","status":"affected"}]}]}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","baseScore":7.5,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":3.6}],"cvssMetricV2":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"2.0","vectorString":"AV:N/AC:L/Au:N/C:N/I:N/A:P","baseScore":5.0,"accessVector":"NETWORK","accessComplexity":"LOW","authentication":"NONE","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"PARTIAL"},"baseSeverity":"MEDIUM","exploitabilityScore":10.0,"impactScore":2.9,"acInsufInfo":false,"obtainAllPrivilege":false,"obtainUserPrivilege":false,"obtainOtherPrivilege":false,"userInteractionRequired":false}]},"weaknesses":[{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-400"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:philips:hue_firmware:*:*:*:*:*:*:*:*","matchCriteriaId":"B32AC3EA-32D2-4DEC-A8D6-82377AB577B3"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:philips:hue:-:*:*:*:*:*:*:*","matchCriteriaId":"E0889CD2-2331-4391-A187-CC64813896DA"}]}]}],"references":[{"url":"http://packetstormsecurity.com/files/160724/Philips-Hue-Denial-Of-Service.html","source":"cve@mitre.org","tags":["Exploit","Third Party Advisory","VDB Entry"]},{"url":"http://seclists.org/fulldisclosure/2020/Dec/51","source":"cve@mitre.org","tags":["Exploit","Mailing List","Third Party Advisory"]},{"url":"https://www.iliashn.com/CVE-2018-7580/","source":"cve@mitre.org","tags":["Exploit","Third Party Advisory"]},{"url":"http://packetstormsecurity.com/files/160724/Philips-Hue-Denial-Of-Service.html","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Exploit","Third Party Advisory","VDB Entry"]},{"url":"http://seclists.org/fulldisclosure/2020/Dec/51","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Exploit","Mailing List","Third Party Advisory"]},{"url":"https://www.iliashn.com/CVE-2018-7580/","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Exploit","Third Party Advisory"]}]}},{"cve":{"id":"CVE-2025-9870","sourceIdentifier":"zdi-disclosures@trendmicro.com","published":"2025-10-29T20:15:37.080","lastModified":"2026-10-08T11:10:00.250","vulnStatus":"Analyzed","cveTags":[],"descriptions":[{"lang":"en","value":"Razer Synapse 3 RazerPhilipsHueUninstall Link Following Local Privilege Escalation Vulnerability. This vulnerability allows local attackers to escalate privileges on affected installations of Razer Synapse 3. An attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability.\n\nThe specific flaw exists within the Philips HUE module installer. By creating a symbolic link, an attacker can abuse the installer to delete arbitrary files. An attacker can leverage this vulnerability to escalate privileges and execute arbitrary code in the context of SYSTEM. Was ZDI-CAN-26375."},{"lang":"es","value":"Razer Synapse 3 RazerPhilipsHueUninstall Link tras una vulnerabilidad de escalada de privilegios local. Esta vulnerabilidad permite a atacantes locales escalar privilegios en instalaciones afectadas de Razer Synapse 3. Un atacante debe primero obtener la capacidad de ejecutar código con privilegios bajos en el sistema objetivo para explotar esta vulnerabilidad.\n\nLa falla específica existe dentro del instalador del módulo Philips HUE. Al crear un enlace simbólico, un atacante puede abusar del instalador para eliminar archivos arbitrarios. Un atacante puede aprovechar esta vulnerabilidad para escalar privilegios y ejecutar código arbitrario en el contexto de SYSTEM. Fue ZDI-CAN-26375."}],"affected":[{"source":"zdi-disclosures@trendmicro.com","affectedData":[{"vendor":"Razer","product":"Synapse 3","defaultStatus":"unknown","versions":[{"version":"3.10.228.21112","status":"affected"}]}]}],"metrics":{"cvssMetricV30":[{"source":"zdi-disclosures@trendmicro.com","type":"Secondary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"timestamp":"2025-10-31T03:55:19.398179Z","id":"CVE-2025-9870","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}]},"weaknesses":[{"source":"zdi-disclosures@trendmicro.com","type":"Secondary","description":[{"lang":"en","value":"CWE-59"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:razer:synapse:*:*:*:*:*:*:*:*","versionEndExcluding":"3.10.730.71519","matchCriteriaId":"3EF1AF2E-84DF-4252-B5F7-DB4DACFBA510"}]}]}],"references":[{"url":"https://www.zerodayinitiative.com/advisories/ZDI-25-921/","source":"zdi-disclosures@trendmicro.com","tags":["Third Party Advisory"]}]}},{"cve":{"id":"CVE-2026-3555","sourceIdentifier":"zdi-disclosures@trendmicro.com","published":"2026-03-16T14:19:48.493","lastModified":"2026-06-17T10:43:46.797","vulnStatus":"Analyzed","cveTags":[],"descriptions":[{"lang":"en","value":"Philips Hue Bridge Zigbee Stack Custom Command Handler Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. User interaction is required to exploit this vulnerability in that the user must initiate the device pairing process.\n\nThe specific flaw exists within the handling of custom Zigbee ZCL frames in the Model Info download functionality. The issue results from the lack of proper validation of the size of data prior to copying it to a fixed-size heap buffer. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-28276."},{"lang":"es","value":"Vulnerabilidad de ejecución remota de código por desbordamiento de búfer basado en montículo en el gestor de comandos personalizado de la pila Zigbee de Philips Hue Bridge. Esta vulnerabilidad permite a atacantes adyacentes a la red ejecutar código arbitrario en instalaciones afectadas de Philips Hue Bridge. Se requiere interacción del usuario para explotar esta vulnerabilidad, ya que el usuario debe iniciar el proceso de emparejamiento del dispositivo.\n\nLa falla específica existe dentro del manejo de tramas Zigbee ZCL personalizadas en la funcionalidad de descarga de información del modelo. El problema resulta de la falta de validación adecuada del tamaño de los datos antes de copiarlos a un búfer de montículo de tamaño fijo. Un atacante puede aprovechar esta vulnerabilidad para ejecutar código en el contexto del dispositivo. Fue ZDI-CAN-28276."}],"affected":[{"source":"zdi-disclosures@trendmicro.com","affectedData":[{"vendor":"Philips","product":"Hue Bridge","defaultStatus":"unknown","versions":[{"version":"1.73.1973146020","status":"affected"}]}]}],"metrics":{"cvssMetricV30":[{"source":"zdi-disclosures@trendmicro.com","type":"Secondary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":8.0,"baseSeverity":"HIGH","attackVector":"ADJACENT_NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.1,"impactScore":5.9}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"timestamp":"2026-03-16T20:15:51.424960Z","id":"CVE-2026-3555","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}]},"weaknesses":[{"source":"zdi-disclosures@trendmicro.com","type":"Secondary","description":[{"lang":"en","value":"CWE-122"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:philips:hue_bridge_v2_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1975170000","matchCriteriaId":"C4C925A5-D9FB-482D-A98D-F879B1BD21EC"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:philips:hue_bridge_v2:-:*:*:*:*:*:*:*","matchCriteriaId":"55B37D18-3A59-423E-9D73-F80DFDB14C4D"}]}]}],"references":[{"url":"https://www.zerodayinitiative.com/advisories/ZDI-26-153/","source":"zdi-disclosures@trendmicro.com","tags":["Third Party Advisory"]}]}},{"cve":{"id":"CVE-2026-3556","sourceIdentifier":"zdi-disclosures@trendmicro.com","published":"2026-03-16T14:19:48.663","lastModified":"2026-06-17T10:43:46.907","vulnStatus":"Analyzed","cveTags":[],"descriptions":[{"lang":"en","value":"Philips Hue Bridge HomeKit Pair-Setup Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the hk_hap_pair_storage_put function. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the HomeKit service. Was ZDI-CAN-28326."},{"lang":"es","value":"Vulnerabilidad de ejecución remota de código por desbordamiento de búfer basado en montículo en el Pair-Setup de HomeKit de Philips Hue Bridge. Esta vulnerabilidad permite a atacantes adyacentes a la red ejecutar código arbitrario en instalaciones afectadas de Philips Hue Bridge. La autenticación no es necesaria para explotar esta vulnerabilidad.\n\nLa falla específica existe dentro de la función hk_hap_pair_storage_put. El problema se debe a la falta de validación adecuada de la longitud de los datos proporcionados por el usuario antes de copiarlos a un búfer de longitud fija basado en montículo. Un atacante puede aprovechar esta vulnerabilidad para ejecutar código en el contexto del servicio HomeKit. Fue ZDI-CAN-28326."}],"affected":[{"source":"zdi-disclosures@trendmicro.com","affectedData":[{"vendor":"Philips","product":"Hue Bridge","defaultStatus":"unknown","versions":[{"version":"1.73.1973146020","status":"affected"}]}]}],"metrics":{"cvssMetricV30":[{"source":"zdi-disclosures@trendmicro.com","type":"Secondary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":8.8,"baseSeverity":"HIGH","attackVector":"ADJACENT_NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.8,"impactScore":5.9}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"timestamp":"2026-03-16T20:16:52.038932Z","id":"CVE-2026-3556","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}]},"weaknesses":[{"source":"zdi-disclosures@trendmicro.com","type":"Secondary","description":[{"lang":"en","value":"CWE-122"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:philips:hue_bridge_v2_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1975170000","matchCriteriaId":"C4C925A5-D9FB-482D-A98D-F879B1BD21EC"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:philips:hue_bridge_v2:-:*:*:*:*:*:*:*","matchCriteriaId":"55B37D18-3A59-423E-9D73-F80DFDB14C4D"}]}]}],"references":[{"url":"https://www.zerodayinitiative.com/advisories/ZDI-26-154/","source":"zdi-disclosures@trendmicro.com","tags":["Third Party Advisory"]}]}},{"cve":{"id":"CVE-2026-3557","sourceIdentifier":"zdi-disclosures@trendmicro.com","published":"2026-03-16T14:19:48.837","lastModified":"2026-06-17T10:43:47.017","vulnStatus":"Analyzed","cveTags":[],"descriptions":[{"lang":"en","value":"Philips Hue Bridge hap_pair_verify_handler Sub-TLV Parsing Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed.\n\nThe specific flaw exists within the hap_pair_verify_handler function of the hk_hap service, which listens on TCP port 8080 by default. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of root. Was ZDI-CAN-28337."},{"lang":"es","value":"Vulnerabilidad de ejecución remota de código por desbordamiento de búfer basado en montículo en el análisis de Sub-TLV de hap_pair_verify_handler de Philips Hue Bridge. Esta vulnerabilidad permite a atacantes adyacentes a la red ejecutar código arbitrario en instalaciones afectadas de Philips Hue Bridge. Aunque se requiere autenticación para explotar esta vulnerabilidad, el mecanismo de autenticación existente puede ser eludido.\n\nLa falla específica existe dentro de la función hap_pair_verify_handler del servicio hk_hap, que escucha en el puerto TCP 8080 por defecto. El problema resulta de la falta de validación adecuada de la longitud de los datos proporcionados por el usuario antes de copiarlos a un búfer basado en montículo. Un atacante puede aprovechar esta vulnerabilidad para ejecutar código en el contexto de root. Fue ZDI-CAN-28337."}],"affected":[{"source":"zdi-disclosures@trendmicro.com","affectedData":[{"vendor":"Philips","product":"Hue Bridge","defaultStatus":"unknown","versions":[{"version":"1.73.1973146020","status":"affected"}]}]}],"metrics":{"cvssMetricV30":[{"source":"zdi-disclosures@trendmicro.com","type":"Secondary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":8.0,"baseSeverity":"HIGH","attackVector":"ADJACENT_NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.1,"impactScore":5.9}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"timestamp":"2026-03-16T20:17:45.866601Z","id":"CVE-2026-3557","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}]},"weaknesses":[{"source":"zdi-disclosures@trendmicro.com","type":"Secondary","description":[{"lang":"en","value":"CWE-122"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:philips:hue_bridge_v2_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1975170000","matchCriteriaId":"C4C925A5-D9FB-482D-A98D-F879B1BD21EC"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:philips:hue_bridge_v2:-:*:*:*:*:*:*:*","matchCriteriaId":"55B37D18-3A59-423E-9D73-F80DFDB14C4D"}]}]}],"references":[{"url":"https://www.zerodayinitiative.com/advisories/ZDI-26-155/","source":"zdi-disclosures@trendmicro.com","tags":["Third Party Advisory"]}]}},{"cve":{"id":"CVE-2026-3558","sourceIdentifier":"zdi-disclosures@trendmicro.com","published":"2026-03-16T14:19:48.997","lastModified":"2026-06-17T10:43:47.123","vulnStatus":"Analyzed","cveTags":[],"descriptions":[{"lang":"en","value":"Philips Hue Bridge HomeKit Accessory Protocol Transient Pairing Mode Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the configuration of the HomeKit Accessory Protocol service, which listens on TCP port 8080 by default. The issue results from the lack of authentication prior to allowing access to functionality. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-28374."},{"lang":"es","value":"Vulnerabilidad de omisión de autenticación en el modo de emparejamiento transitorio del Protocolo de Accesorios HomeKit de Philips Hue Bridge. Esta vulnerabilidad permite a atacantes adyacentes a la red omitir la autenticación en instalaciones afectadas de Philips Hue Bridge. La autenticación no es necesaria para explotar esta vulnerabilidad.\n\nLa falla específica existe dentro de la configuración del servicio del Protocolo de Accesorios HomeKit, que escucha en el puerto TCP 8080 por defecto. El problema resulta de la falta de autenticación antes de permitir el acceso a la funcionalidad. Un atacante puede aprovechar esta vulnerabilidad para omitir la autenticación en el sistema. Fue ZDI-CAN-28374."}],"affected":[{"source":"zdi-disclosures@trendmicro.com","affectedData":[{"vendor":"Philips","product":"Hue Bridge","defaultStatus":"unknown","versions":[{"version":"1.73.1973146020","status":"affected"}]}]}],"metrics":{"cvssMetricV30":[{"source":"zdi-disclosures@trendmicro.com","type":"Secondary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N","baseScore":8.1,"baseSeverity":"HIGH","attackVector":"ADJACENT_NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"NONE"},"exploitabilityScore":2.8,"impactScore":5.2}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"timestamp":"2026-03-16T20:18:31.279335Z","id":"CVE-2026-3558","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}]},"weaknesses":[{"source":"zdi-disclosures@trendmicro.com","type":"Secondary","description":[{"lang":"en","value":"CWE-306"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:philips:hue_bridge_v2_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1975170000","matchCriteriaId":"C4C925A5-D9FB-482D-A98D-F879B1BD21EC"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:philips:hue_bridge_v2:-:*:*:*:*:*:*:*","matchCriteriaId":"55B37D18-3A59-423E-9D73-F80DFDB14C4D"}]}]}],"references":[{"url":"https://www.zerodayinitiative.com/advisories/ZDI-26-156/","source":"zdi-disclosures@trendmicro.com","tags":["Third Party Advisory"]}]}},{"cve":{"id":"CVE-2026-3559","sourceIdentifier":"zdi-disclosures@trendmicro.com","published":"2026-03-16T14:19:51.820","lastModified":"2026-06-17T10:43:47.230","vulnStatus":"Analyzed","cveTags":[],"descriptions":[{"lang":"en","value":"Philips Hue Bridge HomeKit Accessory Protocol Static Nonce Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the configuration of the SRP authentication mechanism in the HomeKit Accessory Protocol service, which listens on TCP port 8080 by default. The issue results from the use of a static nonce value. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-28451."},{"lang":"es","value":"Vulnerabilidad de omisión de autenticación por nonce estático en el Protocolo de Accesorios HomeKit de Philips Hue Bridge. Esta vulnerabilidad permite a atacantes adyacentes a la red omitir la autenticación en instalaciones afectadas de Philips Hue Bridge. La autenticación no es necesaria para explotar esta vulnerabilidad.\n\nLa falla específica reside en la configuración del mecanismo de autenticación SRP en el servicio del Protocolo de Accesorios HomeKit, que escucha en el puerto TCP 8080 por defecto. El problema se debe al uso de un valor nonce estático. Un atacante puede aprovechar esta vulnerabilidad para omitir la autenticación en el sistema. Fue ZDI-CAN-28451."}],"affected":[{"source":"zdi-disclosures@trendmicro.com","affectedData":[{"vendor":"Philips","product":"Hue Bridge","defaultStatus":"unknown","versions":[{"version":"1.73.1973146020","status":"affected"}]}]}],"metrics":{"cvssMetricV30":[{"source":"zdi-disclosures@trendmicro.com","type":"Secondary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N","baseScore":8.1,"baseSeverity":"HIGH","attackVector":"ADJACENT_NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"NONE"},"exploitabilityScore":2.8,"impactScore":5.2}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"timestamp":"2026-03-16T20:19:38.659046Z","id":"CVE-2026-3559","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}]},"weaknesses":[{"source":"zdi-disclosures@trendmicro.com","type":"Secondary","description":[{"lang":"en","value":"CWE-323"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:philips:hue_bridge_v2_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1975170000","matchCriteriaId":"C4C925A5-D9FB-482D-A98D-F879B1BD21EC"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:philips:hue_bridge_v2:-:*:*:*:*:*:*:*","matchCriteriaId":"55B37D18-3A59-423E-9D73-F80DFDB14C4D"}]}]}],"references":[{"url":"https://www.zerodayinitiative.com/advisories/ZDI-26-157/","source":"zdi-disclosures@trendmicro.com","tags":["Third Party Advisory"]}]}},{"cve":{"id":"CVE-2026-3560","sourceIdentifier":"zdi-disclosures@trendmicro.com","published":"2026-03-16T14:19:52.050","lastModified":"2026-06-17T10:43:47.333","vulnStatus":"Analyzed","cveTags":[],"descriptions":[{"lang":"en","value":"Philips Hue Bridge HomeKit hk_hap_pair_storage_put Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the hk_hap_pair_storage_put function of the HomeKit implementation, which listens on TCP port 8080 by default. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-28469."},{"lang":"es","value":"Vulnerabilidad de ejecución remota de código por desbordamiento de búfer basado en montículo hk_hap_pair_storage_put de HomeKit en Philips Hue Bridge. Esta vulnerabilidad permite a atacantes adyacentes a la red ejecutar código arbitrario en instalaciones afectadas de Philips Hue Bridge. La autenticación no es necesaria para explotar esta vulnerabilidad.\n\nLa falla específica existe dentro de la función hk_hap_pair_storage_put de la implementación de HomeKit, que escucha en el puerto TCP 8080 por defecto. El problema resulta de la falta de validación adecuada de la longitud de los datos proporcionados por el usuario antes de copiarlos a un búfer basado en montículo. Un atacante puede aprovechar esta vulnerabilidad para ejecutar código en el contexto del dispositivo. Fue ZDI-CAN-28469."}],"affected":[{"source":"zdi-disclosures@trendmicro.com","affectedData":[{"vendor":"Philips","product":"Hue Bridge","defaultStatus":"unknown","versions":[{"version":"1.73.1973146020","status":"affected"}]}]}],"metrics":{"cvssMetricV30":[{"source":"zdi-disclosures@trendmicro.com","type":"Secondary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":8.8,"baseSeverity":"HIGH","attackVector":"ADJACENT_NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.8,"impactScore":5.9}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"timestamp":"2026-03-16T20:20:11.397148Z","id":"CVE-2026-3560","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}]},"weaknesses":[{"source":"zdi-disclosures@trendmicro.com","type":"Secondary","description":[{"lang":"en","value":"CWE-122"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:philips:hue_bridge_v2_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1975170000","matchCriteriaId":"C4C925A5-D9FB-482D-A98D-F879B1BD21EC"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:philips:hue_bridge_v2:-:*:*:*:*:*:*:*","matchCriteriaId":"55B37D18-3A59-423E-9D73-F80DFDB14C4D"}]}]}],"references":[{"url":"https://www.zerodayinitiative.com/advisories/ZDI-26-158/","source":"zdi-disclosures@trendmicro.com","tags":["Third Party Advisory"]}]}},{"cve":{"id":"CVE-2026-3561","sourceIdentifier":"zdi-disclosures@trendmicro.com","published":"2026-03-16T14:19:52.197","lastModified":"2026-06-17T10:43:47.437","vulnStatus":"Analyzed","cveTags":[],"descriptions":[{"lang":"en","value":"Philips Hue Bridge hk_hap characteristics Heap-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed.\n\nThe specific flaw exists within the handling of PUT requests to the characteristics endpoint. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the device. Was ZDI-CAN-28479."},{"lang":"es","value":"Vulnerabilidad de ejecución remota de código por desbordamiento de búfer basado en montículo en las características hk_hap de Philips Hue Bridge. Esta vulnerabilidad permite a atacantes adyacentes a la red ejecutar código arbitrario en instalaciones afectadas de Philips Hue Bridge. Aunque se requiere autenticación para explotar esta vulnerabilidad, el mecanismo de autenticación existente puede ser eludido.\n\nLa falla específica reside en el manejo de solicitudes PUT al endpoint de características. El problema resulta de la falta de validación adecuada de la longitud de los datos proporcionados por el usuario antes de copiarlos a un búfer basado en montículo. Un atacante puede aprovechar esta vulnerabilidad para ejecutar código en el contexto del dispositivo. Fue ZDI-CAN-28479."}],"affected":[{"source":"zdi-disclosures@trendmicro.com","affectedData":[{"vendor":"Philips","product":"Hue Bridge","defaultStatus":"unknown","versions":[{"version":"1.73.1973146020","status":"affected"}]}]}],"metrics":{"cvssMetricV30":[{"source":"zdi-disclosures@trendmicro.com","type":"Secondary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":8.0,"baseSeverity":"HIGH","attackVector":"ADJACENT_NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.1,"impactScore":5.9}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"timestamp":"2026-03-16T20:20:49.680668Z","id":"CVE-2026-3561","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}]},"weaknesses":[{"source":"zdi-disclosures@trendmicro.com","type":"Secondary","description":[{"lang":"en","value":"CWE-122"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:philips:hue_bridge_v2_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1975170000","matchCriteriaId":"C4C925A5-D9FB-482D-A98D-F879B1BD21EC"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:philips:hue_bridge_v2:-:*:*:*:*:*:*:*","matchCriteriaId":"55B37D18-3A59-423E-9D73-F80DFDB14C4D"}]}]}],"references":[{"url":"https://www.zerodayinitiative.com/advisories/ZDI-26-159/","source":"zdi-disclosures@trendmicro.com","tags":["Third Party Advisory"]}]}},{"cve":{"id":"CVE-2026-3562","sourceIdentifier":"zdi-disclosures@trendmicro.com","published":"2026-03-16T14:19:52.337","lastModified":"2026-06-17T10:43:47.540","vulnStatus":"Analyzed","cveTags":[],"descriptions":[{"lang":"en","value":"Philips Hue Bridge hk_hap Ed25519 Signature Verification Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Philips Hue Bridge. Authentication is not required to exploit this vulnerability.\n\nThe specific flaw exists within the ed25519_sign_open function. The issue results from improper verification of a cryptographic signature. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-28480."},{"lang":"es","value":"Vulnerabilidad de Omisión de Autenticación por Verificación de Firma Ed25519 de hk_hap en Philips Hue Bridge. Esta vulnerabilidad permite a atacantes adyacentes a la red ejecutar código arbitrario en instalaciones afectadas de Philips Hue Bridge. La autenticación no es requerida para explotar esta vulnerabilidad.\n\nLa falla específica existe dentro de la función ed25519_sign_open. El problema resulta de una verificación incorrecta de una firma criptográfica. Un atacante puede aprovechar esta vulnerabilidad para omitir la autenticación en el sistema. Fue ZDI-CAN-28480."}],"affected":[{"source":"zdi-disclosures@trendmicro.com","affectedData":[{"vendor":"Philips","product":"Hue Bridge","defaultStatus":"unknown","versions":[{"version":"1.73.1973146020","status":"affected"}]}]}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":8.8,"baseSeverity":"HIGH","attackVector":"ADJACENT_NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.8,"impactScore":5.9}],"cvssMetricV30":[{"source":"zdi-disclosures@trendmicro.com","type":"Secondary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L","baseScore":6.3,"baseSeverity":"MEDIUM","attackVector":"ADJACENT_NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"LOW","integrityImpact":"LOW","availabilityImpact":"LOW"},"exploitabilityScore":2.8,"impactScore":3.4}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"timestamp":"2026-03-16T20:21:23.637688Z","id":"CVE-2026-3562","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}]},"weaknesses":[{"source":"zdi-disclosures@trendmicro.com","type":"Secondary","description":[{"lang":"en","value":"CWE-347"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:philips:hue_bridge_v2_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"1975170000","matchCriteriaId":"C4C925A5-D9FB-482D-A98D-F879B1BD21EC"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:philips:hue_bridge_v2:-:*:*:*:*:*:*:*","matchCriteriaId":"55B37D18-3A59-423E-9D73-F80DFDB14C4D"}]}]}],"references":[{"url":"https://www.zerodayinitiative.com/advisories/ZDI-26-160/","source":"zdi-disclosures@trendmicro.com","tags":["Third Party Advisory"]}]}},{"cve":{"id":"CVE-2026-73669","sourceIdentifier":"9119a7d8-5eab-497f-8521-727c672e3725","published":"2026-08-13T20:17:30.440","lastModified":"2026-08-26T16:52:20.850","vulnStatus":"Awaiting Analysis","cveTags":[],"descriptions":[{"lang":"en","value":"The Signify Philips Hue Bridge Pro firmware embeds a Mosquitto MQTT broker service that listens on all network interfaces without authentication. An unauthenticated attacker with network access to the MQTT service on a vulnerable system can read data and control connected lights. Fixed in 1.77.2071318010."}],"affected":[{"source":"9119a7d8-5eab-497f-8521-727c672e3725","affectedData":[{"vendor":"Signify","product":"Philips Hue Bridge Pro","defaultStatus":"unknown","versions":[{"version":"0","lessThan":"1.77.2071318010","versionType":"custom","status":"affected"},{"version":"1.77.2071318010","status":"unaffected"}]}]}],"metrics":{"cvssMetricV40":[{"source":"9119a7d8-5eab-497f-8521-727c672e3725","type":"Secondary","cvssData":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":6.9,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"NONE","userInteraction":"NONE","vulnConfidentialityImpact":"LOW","vulnIntegrityImpact":"LOW","vulnAvailabilityImpact":"LOW","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}}],"cvssMetricV31":[{"source":"9119a7d8-5eab-497f-8521-727c672e3725","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L","baseScore":7.3,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"LOW","integrityImpact":"LOW","availabilityImpact":"LOW"},"exploitabilityScore":3.9,"impactScore":3.4}],"ssvcV203":[{"source":"9119a7d8-5eab-497f-8521-727c672e3725","ssvcData":{"timestamp":"2026-08-14T18:59:13.989232Z","id":"CVE-2026-73669","options":[{"exploitation":"none"},{"automatable":"yes"},{"technicalImpact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}},{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"timestamp":"2026-08-17T17:09:44.587019Z","id":"CVE-2026-73669","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}]},"weaknesses":[{"source":"9119a7d8-5eab-497f-8521-727c672e3725","type":"Secondary","description":[{"lang":"en","value":"CWE-306"}]}],"references":[{"url":"https://raw.githubusercontent.com/cisagov/CSAF/develop/csaf_files/IT/white/2026/va-26-225-01.json","source":"9119a7d8-5eab-497f-8521-727c672e3725"},{"url":"https://www.cve.org/CVERecord?id=CVE-2026-73669","source":"9119a7d8-5eab-497f-8521-727c672e3725"},{"url":"https://www.philips-hue.com/en-us/support/release-notes/bridge-pro","source":"9119a7d8-5eab-497f-8521-727c672e3725"},{"url":"https://www.philips-hue.com/en-us/support/security-advisory","source":"9119a7d8-5eab-497f-8521-727c672e3725"}]}}]}