{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-10-27T06:59:20.981","vulnerabilities":[{"cve":{"id":"CVE-2026-55680","sourceIdentifier":"security-advisories@github.com","published":"2026-10-14T20:17:50.193","lastModified":"2026-10-15T16:18:16.273","vulnStatus":"Deferred","cveTags":[],"descriptions":[{"lang":"en","value":"WeGIA is a web manager for charitable institutions. Prior to 3.8.6, unauthenticated POST requests to web/html/socio/sistema/cadastro_cobranca.php can place a quoted SQL expression in the codigo parameter, which extract($_REQUEST) passes into the WHERE codigo= clause of an UPDATE statement without validation or parameter binding. Quoting the value bypasses MariaDB type conversion for the VARCHAR column and permits arbitrary SQL execution without a session. An attacker can read or modify database content, including user credential hashes and billing records in the cobrancas table. This issue is fixed in version 3.8.6."}],"affected":[{"source":"security-advisories@github.com","affectedData":[{"vendor":"LabRedesCefetRJ","product":"WeGIA","versions":[{"version":"< 3.8.6","status":"affected"}]}]}],"metrics":{"cvssMetricV31":[{"source":"security-advisories@github.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":9.8,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":5.9}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"timestamp":"2026-10-15T14:22:39.272170Z","id":"CVE-2026-55680","options":[{"exploitation":"none"},{"automatable":"yes"},{"technicalImpact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}]},"weaknesses":[{"source":"security-advisories@github.com","type":"Secondary","description":[{"lang":"en","value":"CWE-89"}]}],"references":[{"url":"https://github.com/LabRedesCefetRJ/WeGIA/commit/f819be361f984592c4b5a35db830495b4e2263fa","source":"security-advisories@github.com"},{"url":"https://github.com/LabRedesCefetRJ/WeGIA/issues/184","source":"security-advisories@github.com"},{"url":"https://github.com/LabRedesCefetRJ/WeGIA/pull/1705","source":"security-advisories@github.com"},{"url":"https://github.com/LabRedesCefetRJ/WeGIA/releases/tag/3.8.6","source":"security-advisories@github.com"},{"url":"https://github.com/LabRedesCefetRJ/WeGIA/security/advisories/GHSA-fxcc-q2j6-w2rf","source":"security-advisories@github.com"}]}}]}