{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-05-04T19:34:11.255","vulnerabilities":[{"cve":{"id":"CVE-2026-33892","sourceIdentifier":"productcert@siemens.com","published":"2026-04-14T09:16:36.097","lastModified":"2026-04-17T15:24:57.753","vulnStatus":"Awaiting Analysis","cveTags":[],"descriptions":[{"lang":"en","value":"A vulnerability has been identified in Industrial Edge Management Pro V1 (All versions >= V1.7.6 < V1.15.17), Industrial Edge Management Pro V2 (All versions >= V2.0.0 < V2.1.1), Industrial Edge Management Virtual (All versions >= V2.2.0 < V2.8.0). Affected management systems do not properly enforce user authentication on remote connections to devices.\r\nThis could facilitate an unauthenticated remote attacker to circumvent authentication and impersonate a legitimate user.\r\nSuccessful exploitation requires that the attacker has identified the header and port used for remote connections to devices and that the remote connection feature is enabled for the device.\r\n\r\nExploitation allows the attacker to tunnel to the device. Security features on this device itself (e.g. app specific authentication) are not affected."}],"metrics":{"cvssMetricV40":[{"source":"productcert@siemens.com","type":"Secondary","cvssData":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:N/VI:L/VA:N/SC:L/SI:L/SA:L/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":5.1,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"NONE","userInteraction":"ACTIVE","vulnConfidentialityImpact":"NONE","vulnIntegrityImpact":"LOW","vulnAvailabilityImpact":"NONE","subConfidentialityImpact":"LOW","subIntegrityImpact":"LOW","subAvailabilityImpact":"LOW","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}}],"cvssMetricV31":[{"source":"productcert@siemens.com","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:L","baseScore":7.1,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"CHANGED","confidentialityImpact":"LOW","integrityImpact":"LOW","availabilityImpact":"LOW"},"exploitabilityScore":2.8,"impactScore":3.7}]},"weaknesses":[{"source":"productcert@siemens.com","type":"Primary","description":[{"lang":"en","value":"CWE-305"}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-609469.html","source":"productcert@siemens.com"}]}}]}