{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-25T06:43:17.768","vulnerabilities":[{"cve":{"id":"CVE-2026-3315","sourceIdentifier":"db4dfee8-a97e-4877-bfae-eba6d14a2166","published":"2026-03-10T18:19:01.367","lastModified":"2026-03-11T13:53:20.707","vulnStatus":"Awaiting Analysis","cveTags":[],"descriptions":[{"lang":"en","value":"Incorrect Default Permissions, : Execution with Unnecessary Privileges, : Incorrect Permission Assignment for Critical Resource vulnerability in ASSA ABLOY Visionline on Windows allows Configuration/Environment Manipulation.This issue affects Visionline: from 1.0 before 1.33."},{"lang":"es","value":"Permisos Predeterminados Incorrectos, : Ejecución con Privilegios Innecesarios, : Asignación Incorrecta de Permisos para un Recurso Crítico vulnerabilidad en ASSA ABLOY Visionline en Windows permite la Manipulación de la Configuración/Entorno. Este problema afecta a Visionline: desde 1.0 antes de 1.33."}],"metrics":{"cvssMetricV40":[{"source":"db4dfee8-a97e-4877-bfae-eba6d14a2166","type":"Secondary","cvssData":{"version":"4.0","vectorString":"CVSS:4.0/AV:L/AC:L/AT:P/PR:L/UI:N/VC:L/VI:H/VA:L/SC:L/SI:L/SA:L/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:Y/R:U/V:X/RE:L/U:Clear","baseScore":5.8,"baseSeverity":"MEDIUM","attackVector":"LOCAL","attackComplexity":"LOW","attackRequirements":"PRESENT","privilegesRequired":"LOW","userInteraction":"NONE","vulnConfidentialityImpact":"LOW","vulnIntegrityImpact":"HIGH","vulnAvailabilityImpact":"LOW","subConfidentialityImpact":"LOW","subIntegrityImpact":"LOW","subAvailabilityImpact":"LOW","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"YES","Recovery":"USER","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"LOW","providerUrgency":"CLEAR"}}]},"weaknesses":[{"source":"db4dfee8-a97e-4877-bfae-eba6d14a2166","type":"Secondary","description":[{"lang":"en","value":"CWE-250"},{"lang":"en","value":"CWE-276"},{"lang":"en","value":"CWE-732"}]}],"references":[{"url":"https://www.vingcard.com/en/service-and-support/product-security-center/hospitality-product-security-advisories","source":"db4dfee8-a97e-4877-bfae-eba6d14a2166"}]}}]}