{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-19T03:24:26.013","vulnerabilities":[{"cve":{"id":"CVE-2026-32925","sourceIdentifier":"vultures@jpcert.or.jp","published":"2026-04-01T23:17:02.783","lastModified":"2026-04-07T18:27:01.097","vulnStatus":"Analyzed","cveTags":[],"descriptions":[{"lang":"en","value":"V-SFT versions 6.2.10.0 and prior contain a stack-based buffer overflow in VS6ComFile!CV7BaseMap::WriteV7DataToRom. Opening a crafted V7 file may lead to arbitrary code execution on the affected product."}],"metrics":{"cvssMetricV40":[{"source":"vultures@jpcert.or.jp","type":"Secondary","cvssData":{"version":"4.0","vectorString":"CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":8.4,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"NONE","userInteraction":"ACTIVE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnAvailabilityImpact":"HIGH","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}}],"cvssMetricV31":[{"source":"vultures@jpcert.or.jp","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9}]},"weaknesses":[{"source":"vultures@jpcert.or.jp","type":"Primary","description":[{"lang":"en","value":"CWE-121"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:fujielectric:v-sft:*:*:*:*:*:*:*:*","versionEndIncluding":"6.2.10.0","matchCriteriaId":"36E67AE4-958D-4DA7-B5E2-95A3BDD29BF6"}]}]}],"references":[{"url":"https://felib.fujielectric.co.jp/en/M10010/M20060/document_detail/5d9dd71d-9494-41a4-aa5c-8e6b8b21066b?region=en-glb","source":"vultures@jpcert.or.jp","tags":["Release Notes"]},{"url":"https://jvn.jp/en/vu/JVNVU90448293/","source":"vultures@jpcert.or.jp","tags":["Third Party Advisory"]}]}}]}