{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-17T23:13:20.985","vulnerabilities":[{"cve":{"id":"CVE-2026-25655","sourceIdentifier":"productcert@siemens.com","published":"2026-02-10T10:15:59.700","lastModified":"2026-02-12T15:27:28.540","vulnStatus":"Analyzed","cveTags":[],"descriptions":[{"lang":"en","value":"A vulnerability has been identified in SINEC NMS (All versions < V4.0 SP2). The affected application permits improper modification of a configuration file by a low-privileged user.\r\nThis could allow an attacker to load malicious DLLs, potentially leading to arbitrary code execution with administrative privilege.(ZDI-CAN-28107)"},{"lang":"es","value":"Una vulnerabilidad ha sido identificada en SINEC NMS (Todas las versiones &lt; V4.0 SP2). La aplicación afectada permite la modificación indebida de un archivo de configuración por un usuario de bajo privilegio. Esto podría permitir a un atacante cargar DLLs maliciosas, lo que podría llevar a la ejecución de código arbitrario con privilegios administrativos. (ZDI-CAN-28107)"}],"metrics":{"cvssMetricV40":[{"source":"productcert@siemens.com","type":"Secondary","cvssData":{"version":"4.0","vectorString":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":8.5,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"LOW","userInteraction":"NONE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnAvailabilityImpact":"HIGH","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}}],"cvssMetricV31":[{"source":"productcert@siemens.com","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9}]},"weaknesses":[{"source":"productcert@siemens.com","type":"Primary","description":[{"lang":"en","value":"CWE-427"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:sinec_nms:*:*:*:*:*:*:*:*","versionEndExcluding":"4.0","matchCriteriaId":"7B9143A8-0ED9-467A-9138-2D2CCB9ADC84"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:sinec_nms:4.0:-:*:*:*:*:*:*","matchCriteriaId":"2767CF34-75A7-449A-AD39-B7BF58A2EF60"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:sinec_nms:4.0:sp1:*:*:*:*:*:*","matchCriteriaId":"AF775FB0-A9C1-4305-9063-5FC97E081758"}]}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-311973.html","source":"productcert@siemens.com","tags":["Vendor Advisory"]}]}}]}