{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-24T16:56:36.398","vulnerabilities":[{"cve":{"id":"CVE-2026-1875","sourceIdentifier":"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp","published":"2026-03-03T07:16:10.277","lastModified":"2026-04-24T08:16:29.703","vulnStatus":"Undergoing Analysis","cveTags":[],"descriptions":[{"lang":"en","value":"Improper Resource Shutdown or Release vulnerability in Mitsubishi Electric Corporation MELSEC iQ-F Series FX5-EIP EtherNet/IP Module FX5-EIP versions 1.000 and prior allows a remote attacker to cause a denial-of-service (DoS) condition on the products by continuously sending UDP packets to the products. A system reset of the product is required for recovery."},{"lang":"es","value":"Vulnerabilidad de cierre o liberación inadecuados de recursos en Mitsubishi Electric Corporation MELSEC iQ-F Series FX5-EIP EtherNet/IP Module FX5-EIP todas las versiones permite a un atacante remoto causar una condición de denegación de servicio (DoS) en los productos mediante el envío continuo de paquetes UDP a los productos. Se requiere un reinicio del sistema del producto para la recuperación."}],"metrics":{"cvssMetricV40":[{"source":"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp","type":"Secondary","cvssData":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":8.7,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"NONE","userInteraction":"NONE","vulnConfidentialityImpact":"NONE","vulnIntegrityImpact":"NONE","vulnAvailabilityImpact":"HIGH","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}}]},"weaknesses":[{"source":"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp","type":"Secondary","description":[{"lang":"en","value":"CWE-404"}]}],"references":[{"url":"https://jvn.jp/vu/JVNVU93286687/","source":"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp"},{"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-26-62-01","source":"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp"},{"url":"https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2025-021_en.pdf","source":"Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp"}]}}]}