{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-11-25T17:48:54.106","vulnerabilities":[{"cve":{"id":"CVE-2026-129713","sourceIdentifier":"d7ff35af-cf88-454c-bab9-af60602f10f8","published":"2026-11-20T11:18:30.953","lastModified":"2026-11-24T17:50:07.100","vulnStatus":"Awaiting Analysis","cveTags":[],"descriptions":[{"lang":"en","value":"A stack-based buffer overflow in an unauthenticated CGI handler of the\nDanfoss AK-SM 8xxA Series controller allows remote attackers to send specially\ncrafted HTTP/S POST requests, leading to memory corruption, webserver restart\nand hypothetically potential arbitrary code execution with webserver privileges.\nAuthentication is not required to exploit this vulnerability."}],"affected":[{"source":"d7ff35af-cf88-454c-bab9-af60602f10f8","affectedData":[{"vendor":"Danfoss","product":"AK-SM8xxA","defaultStatus":"unaffected","versions":[{"version":"0","lessThanOrEqual":"5.4.0","versionType":"custom","status":"affected"}]}]}],"metrics":{"cvssMetricV40":[{"source":"d7ff35af-cf88-454c-bab9-af60602f10f8","type":"Secondary","cvssData":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":9.3,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"NONE","userInteraction":"NONE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnAvailabilityImpact":"HIGH","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}}]},"weaknesses":[{"source":"d7ff35af-cf88-454c-bab9-af60602f10f8","type":"Secondary","description":[{"lang":"en","value":"CWE-121"}]}],"references":[{"url":"https://www.danfoss.com/en/service-and-support/coordinated-vulnerability-disclosure/danfoss-security-advisories/dsa-2026-12-01/","source":"d7ff35af-cf88-454c-bab9-af60602f10f8"}]}}]}