{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-11-21T18:55:43.932","vulnerabilities":[{"cve":{"id":"CVE-2026-118462","sourceIdentifier":"a6d3dc9e-0591-4a13-bce7-0f5b31ff6158","published":"2026-11-09T12:16:37.130","lastModified":"2026-11-12T20:18:18.117","vulnStatus":"Deferred","cveTags":[],"descriptions":[{"lang":"en","value":"Update components download and execute code without proper authenticity verification, relying on ignored hashes or forgeable checksums. Some update paths also permit archive traversal or script execution."}],"affected":[{"source":"a6d3dc9e-0591-4a13-bce7-0f5b31ff6158","affectedData":[{"vendor":"CompuGroup Medical","product":"Infantia","defaultStatus":"unknown","packageName":"cgm.files.delivery","versions":[{"version":"0","lessThanOrEqual":"1.3.0","versionType":"semver","status":"affected"}]},{"vendor":"CompuGroup Medical","product":"Profim","defaultStatus":"unknown","packageName":"cgm.files.delivery","versions":[{"version":"0","lessThanOrEqual":"1.3.0","versionType":"semver","status":"affected"}]},{"vendor":"CompuGroup Medical","product":"Venere","defaultStatus":"unknown","packageName":"cgm.files.delivery","versions":[{"version":"0","lessThanOrEqual":"1.3.0","versionType":"semver","status":"affected"}]},{"vendor":"CompuGroup Medical","product":"Phronesis","defaultStatus":"unknown","packageName":"cgm.files.delivery","versions":[{"version":"0","lessThanOrEqual":"1.3.0","versionType":"semver","status":"affected"}]},{"vendor":"CompuGroup Medical","product":"Infantia","defaultStatus":"unknown","packageName":"cgm.liveupdates","versions":[{"version":"0","lessThanOrEqual":"2.12.0","versionType":"semver","status":"affected"}]},{"vendor":"CompuGroup Medical","product":"Profim","defaultStatus":"unknown","packageName":"cgm.liveupdates","versions":[{"version":"0","lessThanOrEqual":"2.12.0","versionType":"semver","status":"affected"}]},{"vendor":"CompuGroup Medical","product":"Venere","defaultStatus":"unknown","packageName":"cgm.liveupdates","versions":[{"version":"0","lessThanOrEqual":"2.12.0","versionType":"semver","status":"affected"}]},{"vendor":"CompuGroup Medical","product":"Phronesis","defaultStatus":"unknown","packageName":"cgm.liveupdates","versions":[{"version":"0","lessThanOrEqual":"2.12.0","versionType":"semver","status":"affected"}]}]}],"metrics":{"cvssMetricV40":[{"source":"a6d3dc9e-0591-4a13-bce7-0f5b31ff6158","type":"Secondary","cvssData":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:H/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":9.2,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"HIGH","attackRequirements":"PRESENT","privilegesRequired":"NONE","userInteraction":"NONE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnAvailabilityImpact":"HIGH","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"timestamp":"2026-11-12T19:58:38.503243Z","id":"CVE-2026-118462","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}]},"weaknesses":[{"source":"a6d3dc9e-0591-4a13-bce7-0f5b31ff6158","type":"Secondary","description":[{"lang":"en","value":"CWE-494"}]}],"references":[{"url":"https://www.acn.gov.it/portale/w/rilevate-vulnerabilita-in-prodotti-compugroup-medical","source":"a6d3dc9e-0591-4a13-bce7-0f5b31ff6158"},{"url":"https://www.cgm.com/ita_it/magazine/articles/comunicati-stampa/piu-sicurezza-per-farmacie-studi-medici-e-pazienti-cgm-italia-risolve-potenziali-vulnerabilita-software-insieme-a-csirt-italia.html","source":"a6d3dc9e-0591-4a13-bce7-0f5b31ff6158"}]}}]}