{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-06-15T22:02:36.559","vulnerabilities":[{"cve":{"id":"CVE-2025-8472","sourceIdentifier":"zdi-disclosures@trendmicro.com","published":"2025-08-01T18:15:57.450","lastModified":"2025-08-12T18:10:27.140","vulnStatus":"Analyzed","cveTags":[],"descriptions":[{"lang":"en","value":"Alpine iLX-507 vCard Parsing Stack-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Alpine iLX-507 devices. User interaction is required to exploit this vulnerability in that the target must connect to a malicious Bluetooth device.\n\nThe specific flaw exists within the parsing of vCard data. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a stack-based buffer. An attacker can leverage this vulnerability to execute arbitrary code in the context of root. Was ZDI-CAN-26316."},{"lang":"es","value":"Vulnerabilidad de ejecución remota de código por desbordamiento de búfer basado en pila al analizar vCard en Alpine iLX-507. Esta vulnerabilidad permite a atacantes adyacentes a la red ejecutar código arbitrario en las instalaciones afectadas de los dispositivos Alpine iLX-507. Para explotar esta vulnerabilidad, se requiere la interacción del usuario, ya que el objetivo debe conectarse a un dispositivo Bluetooth malicioso. La falla específica se encuentra en el análisis de datos vCard. El problema se debe a la falta de una validación adecuada de la longitud de los datos proporcionados por el usuario antes de copiarlos a un búfer basado en pila. Un atacante puede aprovechar esta vulnerabilidad para ejecutar código arbitrario en el contexto de root. Anteriormente, se denominó ZDI-CAN-26316."}],"metrics":{"cvssMetricV30":[{"source":"zdi-disclosures@trendmicro.com","type":"Secondary","cvssData":{"version":"3.0","vectorString":"CVSS:3.0/AV:A/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H","baseScore":7.4,"baseSeverity":"HIGH","attackVector":"ADJACENT_NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.5,"impactScore":5.9}]},"weaknesses":[{"source":"zdi-disclosures@trendmicro.com","type":"Secondary","description":[{"lang":"en","value":"CWE-121"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:alpsalpine:ilx-507_firmware:6.0.000:*:*:*:*:*:*:*","matchCriteriaId":"AF7ECB73-21CD-4AA6-83A2-58B218BB7443"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:alpsalpine:ilx-507:-:*:*:*:*:*:*:*","matchCriteriaId":"1E89A5FC-D1BE-4967-A581-BFC98FAA79E0"}]}]}],"references":[{"url":"https://www.zerodayinitiative.com/advisories/ZDI-25-761/","source":"zdi-disclosures@trendmicro.com","tags":["Third Party Advisory"]}]}}]}