{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-22T05:29:49.430","vulnerabilities":[{"cve":{"id":"CVE-2025-8008","sourceIdentifier":"PSIRT@rockwellautomation.com","published":"2025-09-09T13:15:32.317","lastModified":"2025-09-17T15:42:27.340","vulnStatus":"Analyzed","cveTags":[],"descriptions":[{"lang":"en","value":"A security issue exists in the protected mode of EN4TR devices, where sending specifically crafted messages during a Forward Close operation can cause the device to crash."}],"metrics":{"cvssMetricV40":[{"source":"PSIRT@rockwellautomation.com","type":"Secondary","cvssData":{"version":"4.0","vectorString":"CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":7.1,"baseSeverity":"HIGH","attackVector":"ADJACENT","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"NONE","userInteraction":"NONE","vulnConfidentialityImpact":"NONE","vulnIntegrityImpact":"NONE","vulnAvailabilityImpact":"HIGH","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}}],"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","baseScore":6.5,"baseSeverity":"MEDIUM","attackVector":"ADJACENT_NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH"},"exploitabilityScore":2.8,"impactScore":3.6}]},"weaknesses":[{"source":"PSIRT@rockwellautomation.com","type":"Secondary","description":[{"lang":"en","value":"CWE-755"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:rockwellautomation:1756-en2tr_series_a_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"7.001","matchCriteriaId":"BC8989AE-74A8-47FD-9B4F-B36237269F29"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:rockwellautomation:1756-en2tr_series_a:-:*:*:*:*:*:*:*","matchCriteriaId":"A4A8E21A-3826-497C-9F3D-6D9091AD7647"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:rockwellautomation:1756-en2tr_series_b_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"7.001","matchCriteriaId":"AD19C174-342C-47AD-ACBF-AA6AF7888FB2"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:rockwellautomation:1756-en2tr_series_b:-:*:*:*:*:*:*:*","matchCriteriaId":"8607CD0D-0EE7-41CF-8E00-C0F5C83646A8"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:rockwellautomation:1756-en2tr_series_c_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"7.001","matchCriteriaId":"04E47C93-7572-4E18-A151-08913E7AC24F"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:rockwellautomation:1756-en2tr_series_c:-:*:*:*:*:*:*:*","matchCriteriaId":"D58BA41B-3859-4489-9C74-730C27B1EFF0"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:rockwellautomation:1756-en4tr_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"7.001","matchCriteriaId":"9A12969D-C3DA-4E4D-B344-1797D4B77A70"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:rockwellautomation:1756-en4tr:-:*:*:*:*:*:*:*","matchCriteriaId":"898EE953-E0EF-4B52-8EA0-41AAD8B5CCF3"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:rockwellautomation:1756-en4trxt_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"7.001","matchCriteriaId":"C08577B2-133E-46C7-811F-00D45C49B5B3"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:rockwellautomation:1756-en4trxt:-:*:*:*:*:*:*:*","matchCriteriaId":"E45471FA-99BF-4F57-BFC8-224BB9576670"}]}]}],"references":[{"url":"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1739.html","source":"PSIRT@rockwellautomation.com","tags":["Vendor Advisory"]}]}}]}