{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-18T17:04:03.369","vulnerabilities":[{"cve":{"id":"CVE-2025-66052","sourceIdentifier":"cvd@cert.pl","published":"2026-01-09T12:15:53.883","lastModified":"2026-01-14T17:50:09.087","vulnStatus":"Analyzed","cveTags":[{"sourceIdentifier":"cvd@cert.pl","tags":["unsupported-when-assigned"]}],"descriptions":[{"lang":"en","value":"Vivotek IP7137 camera with firmware version 0200a is vulnerable to command injection. Parameter \"system_ntpIt\" used by \"/cgi-bin/admin/setparam.cgi\" endpoint is not sanitized properly, allowing a user with administrative privileges to perform an attack. Due to CVE-2025-66050, administrative access is not protected by default, \nThe vendor has not replied to the CNA Possibly all firmware versions are affected. Since the product has met End-Of-Life phase, a fix is not expected to be released."},{"lang":"es","value":"La cámara Vivotek IP7137 con la versión de firmware 0200a es vulnerable a inyección de comandos. El parámetro 'system_ntpIt' utilizado por el endpoint /cgi-bin/admin/setparam.cgi no se sanea correctamente, permitiendo que un usuario con privilegios administrativos realice un ataque. Debido a CVE-2025-66050, el acceso administrativo no está protegido por defecto. El proveedor no ha respondido a la CNA. Posiblemente todas las versiones de firmware están afectadas. Dado que el producto ha alcanzado la fase de Fin de Vida Útil, no se espera que se lance una solución."}],"metrics":{"cvssMetricV40":[{"source":"cvd@cert.pl","type":"Secondary","cvssData":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":8.6,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"HIGH","userInteraction":"NONE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnAvailabilityImpact":"HIGH","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}}],"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","baseScore":7.2,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"HIGH","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.2,"impactScore":5.9}]},"weaknesses":[{"source":"cvd@cert.pl","type":"Primary","description":[{"lang":"en","value":"CWE-78"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:vivotek:ip7137_firmware:0200a:*:*:*:*:*:*:*","matchCriteriaId":"7FBD8C69-D2F8-46B0-AE09-F6296BD22414"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:vivotek:ip7137:-:*:*:*:*:*:*:*","matchCriteriaId":"2BE1F29C-4CF4-46B7-862B-C4B3F00B70EE"}]}]}],"references":[{"url":"https://cert.pl/posts/2026/01/CVE-2025-66049","source":"cvd@cert.pl","tags":["Third Party Advisory"]}]}}]}