{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-06-16T07:41:34.089","vulnerabilities":[{"cve":{"id":"CVE-2025-6505","sourceIdentifier":"security@progress.com","published":"2025-07-29T13:15:28.807","lastModified":"2025-10-02T17:40:32.977","vulnStatus":"Analyzed","cveTags":[],"descriptions":[{"lang":"en","value":"Unauthorized access and impersonation can occur in versions 4.6.2.3226 and below of Progress Software's Hybrid Data Pipeline Server on Linux. This vulnerability allows attackers to combine credentials from different sources, potentially leading to client impersonation and unauthorized access.\n When OAuth Clients perform an OAuth handshake with the Hybrid Data Pipeline Server, the server accepts client credentials from both HTTP headers and request parameters."},{"lang":"es","value":"El acceso no autorizado y la suplantación de identidad pueden ocurrir en las versiones 4.6.2.3226 y anteriores de Progress Software's Hybrid Data Pipeline Server en Linux. Esta vulnerabilidad permite a los atacantes combinar credenciales de diferentes fuentes, lo que podría provocar la suplantación de identidad del cliente y el acceso no autorizado. Cuando los clientes OAuth realizan un protocolo de enlace OAuth con el servidor Hybrid Data Pipeline, este acepta las credenciales del cliente tanto de los encabezados HTTP como de los parámetros de solicitud."}],"metrics":{"cvssMetricV31":[{"source":"security@progress.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":8.1,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"HIGH","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.2,"impactScore":5.9}]},"weaknesses":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","type":"Secondary","description":[{"lang":"en","value":"CWE-287"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:progress:hybrid_data_pipeline:*:*:*:*:*:*:*:*","versionEndExcluding":"4.6.2.3275","matchCriteriaId":"5C2C0346-4B4C-4AB9-A697-C15F8D2D3FED"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:o:linux:linux_kernel:-:*:*:*:*:*:*:*","matchCriteriaId":"703AF700-7A70-47E2-BC3A-7FD03B3CA9C1"}]}]}],"references":[{"url":"https://community.progress.com/s/article/DataDirect-Hybrid-Data-Pipeline-Critical-Security-Product-Alert-Bulletin-July-2025---CVE-2025-6505","source":"security@progress.com","tags":["Vendor Advisory"]}]}}]}