{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-06-25T01:18:07.356","vulnerabilities":[{"cve":{"id":"CVE-2025-57219","sourceIdentifier":"cve@mitre.org","published":"2025-08-28T19:15:33.813","lastModified":"2026-06-17T09:42:57.560","vulnStatus":"Analyzed","cveTags":[],"descriptions":[{"lang":"en","value":"Incorrect access control in the endpoint /goform/ate of Tenda AC10 v4.0 firmware v16.03.10.09_multi_TDE01 allows attackers to escalate privileges or access sensitive components via a crafted request."},{"lang":"es","value":"Control de acceso incorrecto en el endpoint /goform/ate del firmware v16.03.10.09_multi_TDE01 de Tenda AC10 v4.0 permite a los atacantes escalar privilegios o acceder a componentes sensibles mediante una solicitud manipulada."}],"affected":[{"source":"cve@mitre.org","affectedData":[{"vendor":"n/a","product":"n/a","versions":[{"version":"n/a","status":"affected"}]}]}],"metrics":{"cvssMetricV31":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N","baseScore":5.3,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"LOW","integrityImpact":"NONE","availabilityImpact":"NONE"},"exploitabilityScore":3.9,"impactScore":1.4}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"timestamp":"2025-08-28T19:56:16.023454Z","id":"CVE-2025-57219","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}]},"weaknesses":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","type":"Secondary","description":[{"lang":"en","value":"CWE-284"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:tenda:ac10_firmware:16.03.10.09_multi_tde01:*:*:*:*:*:*:*","matchCriteriaId":"924C096B-96A6-43BF-A718-EB339D76E655"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:tenda:ac10:4.0:*:*:*:*:*:*:*","matchCriteriaId":"970AEBF4-2B32-4633-A75B-2D2C598C048D"}]}]}],"references":[{"url":"https://plaid-knot-11b.notion.site/Unauthenticated-Remote-Access-to-ate-Debug-Interface-via-Improper-Access-Controls-in-Tenda-AC10-V4-23fb3e9cce328050a479e44a8c217a72?source=copy_link","source":"cve@mitre.org","tags":["Third Party Advisory"]}]}}]}