{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-05-01T05:34:04.589","vulnerabilities":[{"cve":{"id":"CVE-2025-53702","sourceIdentifier":"cvd@cert.pl","published":"2025-10-23T14:15:39.267","lastModified":"2025-11-04T13:10:40.083","vulnStatus":"Analyzed","cveTags":[{"sourceIdentifier":"cvd@cert.pl","tags":["unsupported-when-assigned"]}],"descriptions":[{"lang":"en","value":"Vilar VS-IPC1002 IP cameras are vulnerable to DoS (Denial-of-Service) attacks. An unauthenticated attacker on the same local network might send a crafted request to /cgi-bin/action endpoint and render the device completely unresponsive. A manual restart of the device is required. \nThe vendor did not respond in any way. Only version 1.1.0.18 was tested, other versions might be vulnerable as well."}],"metrics":{"cvssMetricV40":[{"source":"cvd@cert.pl","type":"Secondary","cvssData":{"version":"4.0","vectorString":"CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":7.1,"baseSeverity":"HIGH","attackVector":"ADJACENT","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"NONE","userInteraction":"NONE","vulnConfidentialityImpact":"NONE","vulnIntegrityImpact":"NONE","vulnAvailabilityImpact":"HIGH","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}}],"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","baseScore":6.5,"baseSeverity":"MEDIUM","attackVector":"ADJACENT_NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH"},"exploitabilityScore":2.8,"impactScore":3.6}]},"weaknesses":[{"source":"cvd@cert.pl","type":"Secondary","description":[{"lang":"en","value":"CWE-755"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:vimicro:vs-ipc1002_firmware:1.1.0.18:*:*:*:*:*:*:*","matchCriteriaId":"BFF3572F-8791-43CE-A735-95568316F29B"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:vimicro:vs-ipc1002:-:*:*:*:*:*:*:*","matchCriteriaId":"A7B7DA5F-FE1C-461D-A957-60AB93BAD83F"}]}]}],"references":[{"url":"https://cert.pl/en/posts/2025/10/CVE-2025-53701","source":"cvd@cert.pl","tags":["Third Party Advisory"]}]}}]}