{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-05-08T17:09:48.135","vulnerabilities":[{"cve":{"id":"CVE-2025-52586","sourceIdentifier":"ics-cert@hq.dhs.gov","published":"2025-08-08T16:15:27.617","lastModified":"2026-04-15T00:35:42.020","vulnStatus":"Deferred","cveTags":[],"descriptions":[{"lang":"en","value":"The MOD3 command traffic between the monitoring application and the \ninverter is transmitted in plaintext without encryption or obfuscation. \nThis vulnerability may allow an attacker with access to a local network \nto intercept, manipulate, replay, or forge critical data, including \nread/write operations for voltage, current, and power configuration, \noperational status, alarms, telemetry, system reset, or inverter control\n commands, potentially disrupting power generation or reconfiguring \ninverter settings."},{"lang":"es","value":"El tráfico de comandos MOD3 entre la aplicación de monitorización y el inversor se transmite en texto plano, sin cifrado ni ofuscación. Esta vulnerabilidad podría permitir que un atacante con acceso a una red local intercepte, manipule, reproduzca o falsifique datos críticos, como operaciones de lectura/escritura de voltaje, corriente y configuración de potencia, estado operativo, alarmas, telemetría, reinicio del sistema o comandos de control del inversor, lo que podría interrumpir la generación de energía o reconfigurar los ajustes del inversor."}],"metrics":{"cvssMetricV40":[{"source":"ics-cert@hq.dhs.gov","type":"Secondary","cvssData":{"version":"4.0","vectorString":"CVSS:4.0/AV:L/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":7.5,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","attackRequirements":"PRESENT","privilegesRequired":"NONE","userInteraction":"NONE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnAvailabilityImpact":"LOW","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}}],"cvssMetricV31":[{"source":"ics-cert@hq.dhs.gov","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:L","baseScore":6.9,"baseSeverity":"MEDIUM","attackVector":"LOCAL","attackComplexity":"HIGH","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"LOW"},"exploitabilityScore":1.4,"impactScore":5.5}]},"weaknesses":[{"source":"ics-cert@hq.dhs.gov","type":"Secondary","description":[{"lang":"en","value":"CWE-319"}]}],"references":[{"url":"https://eg4electronics.com/contact/","source":"ics-cert@hq.dhs.gov"},{"url":"https://eg4electronics.com/wp-content/uploads/2025/09/EG4-Wi-Fi-Dongle-Dongle-Firmware-Update.pdf","source":"ics-cert@hq.dhs.gov"},{"url":"https://www.cisa.gov/news-events/ics-advisories/icsa-25-219-07","source":"ics-cert@hq.dhs.gov"}]}}]}