{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-08-01T07:49:24.889","vulnerabilities":[{"cve":{"id":"CVE-2025-48015","sourceIdentifier":"security@selinc.com","published":"2025-05-20T16:15:35.143","lastModified":"2026-06-17T09:29:01.237","vulnStatus":"Deferred","cveTags":[],"descriptions":[{"lang":"en","value":"Failed login response could be different depending on whether the username was local or central."},{"lang":"es","value":"La respuesta en caso de inicio de sesión fallido podría ser diferente dependiendo de si el nombre de usuario era local o central."}],"affected":[{"source":"security@selinc.com","affectedData":[{"vendor":"Schweitzer Engineering Laboratories","product":"SEL-5056 Software-Defined Network Flow Controller","defaultStatus":"unaffected","versions":[{"version":"0","lessThan":"2.16.0","versionType":"custom","status":"affected"}]}]}],"metrics":{"cvssMetricV31":[{"source":"security@selinc.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:N/A:N","baseScore":3.7,"baseSeverity":"LOW","attackVector":"NETWORK","attackComplexity":"HIGH","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"LOW","integrityImpact":"NONE","availabilityImpact":"NONE"},"exploitabilityScore":2.2,"impactScore":1.4}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"timestamp":"2025-05-20T15:55:22.553964Z","id":"CVE-2025-48015","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}]},"weaknesses":[{"source":"security@selinc.com","type":"Secondary","description":[{"lang":"en","value":"CWE-204"}]}],"references":[{"url":"https://selinc.com/products/software/latest-software-versions/","source":"security@selinc.com"}]}}]}