{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-19T23:35:13.203","vulnerabilities":[{"cve":{"id":"CVE-2025-43022","sourceIdentifier":"hp-security-alert@hp.com","published":"2025-07-22T23:15:24.810","lastModified":"2025-10-02T17:43:39.780","vulnStatus":"Analyzed","cveTags":[],"descriptions":[{"lang":"en","value":"A potential SQL injection vulnerability has been identified in the Poly\nClariti Manager for versions prior to 10.12.1. The vulnerability could allow\na privileged user to execute SQL commands. HP has addressed the issue in\nthe latest software update."},{"lang":"es","value":"Se ha identificado una posible vulnerabilidad de inyección SQL en Poly Clariti Manager para versiones anteriores a la 10.12.1. Esta vulnerabilidad podría permitir que un usuario con privilegios ejecute comandos SQL. HP ha solucionado el problema en la última actualización de software."}],"metrics":{"cvssMetricV40":[{"source":"hp-security-alert@hp.com","type":"Secondary","cvssData":{"version":"4.0","vectorString":"CVSS:4.0/AV:A/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:L/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":7.3,"baseSeverity":"HIGH","attackVector":"ADJACENT","attackComplexity":"LOW","attackRequirements":"PRESENT","privilegesRequired":"HIGH","userInteraction":"NONE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnAvailabilityImpact":"HIGH","subConfidentialityImpact":"LOW","subIntegrityImpact":"LOW","subAvailabilityImpact":"LOW","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}}],"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","baseScore":7.2,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"HIGH","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.2,"impactScore":5.9}]},"weaknesses":[{"source":"hp-security-alert@hp.com","type":"Secondary","description":[{"lang":"en","value":"CWE-89"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:hp:poly_clariti_manager:*:*:*:*:*:*:*:*","versionEndExcluding":"10.12.2","matchCriteriaId":"82C289E5-06F3-48F9-8C75-6CCFE4686F5C"}]}]}],"references":[{"url":"https://support.hp.com/us-en/document/ish_12781425-12781447-16/hbsbpy04037","source":"hp-security-alert@hp.com","tags":["Vendor Advisory"]}]}}]}