{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-18T19:01:01.706","vulnerabilities":[{"cve":{"id":"CVE-2025-41370","sourceIdentifier":"cve-coordination@incibe.es","published":"2025-08-01T13:15:25.250","lastModified":"2025-10-08T18:33:44.963","vulnStatus":"Analyzed","cveTags":[],"descriptions":[{"lang":"en","value":"A SQL injection vulnerability has been found in Gandia Integra Total of TESI from version 2.1.2217.3 to v4.4.2236.1. The vulnerability allows an authenticated attacker to retrieve, create, update and delete databases through the 'idestudio' parameter in /encuestas/integraweb/html/view/acceso.php."},{"lang":"es","value":"Se ha detectado una vulnerabilidad de inyección SQL en Gandia Integra Total of TESI, desde la versión 2.1.2217.3 hasta la v4.4.2236.1. Esta vulnerabilidad permite a un atacante autenticado recuperar, crear, actualizar y eliminar bases de datos mediante el parámetro 'idestudio' en /encuestas/integraweb/html/view/acceso.php."}],"metrics":{"cvssMetricV40":[{"source":"cve-coordination@incibe.es","type":"Secondary","cvssData":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":9.3,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"NONE","userInteraction":"NONE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnAvailabilityImpact":"HIGH","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}}],"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":8.8,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.8,"impactScore":5.9}]},"weaknesses":[{"source":"cve-coordination@incibe.es","type":"Secondary","description":[{"lang":"en","value":"CWE-89"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:tesigandia:gandia_integra_total:*:*:*:*:*:*:*:*","versionStartIncluding":"2.1.2217.3","versionEndIncluding":"4.4.2236.1","matchCriteriaId":"B99DA4EE-BA6F-44B5-9027-BC26C5130D34"}]}]}],"references":[{"url":"https://www.incibe.es/en/incibe-cert/notices/aviso/multiple-vulnerabilities-gandia-integra-total-tesi","source":"cve-coordination@incibe.es","tags":["Third Party Advisory"]}]}}]}