{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-16T18:36:31.816","vulnerabilities":[{"cve":{"id":"CVE-2025-40838","sourceIdentifier":"85b1779b-6ecd-4f52-bcc5-73eac4659dcf","published":"2025-09-25T15:16:11.587","lastModified":"2025-10-02T17:58:17.850","vulnStatus":"Analyzed","cveTags":[],"descriptions":[{"lang":"en","value":"Ericsson Indoor Connect 8855 contains a vulnerability where server-side security can be bypassed in the client which if exploited can lead to unauthorized disclosure of certain information."}],"metrics":{"cvssMetricV40":[{"source":"85b1779b-6ecd-4f52-bcc5-73eac4659dcf","type":"Secondary","cvssData":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:N/VI:N/VA:N/SC:L/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":2.0,"baseSeverity":"LOW","attackVector":"NETWORK","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"HIGH","userInteraction":"NONE","vulnConfidentialityImpact":"NONE","vulnIntegrityImpact":"NONE","vulnAvailabilityImpact":"NONE","subConfidentialityImpact":"LOW","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}}],"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N","baseScore":7.5,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"NONE","availabilityImpact":"NONE"},"exploitabilityScore":3.9,"impactScore":3.6}]},"weaknesses":[{"source":"85b1779b-6ecd-4f52-bcc5-73eac4659dcf","type":"Secondary","description":[{"lang":"en","value":"CWE-522"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:ericsson:indoor_connect_8855_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"2025.q2","matchCriteriaId":"6C4EA917-1899-4713-AE19-50412249505A"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:ericsson:indoor_connect_8855:-:*:*:*:*:*:*:*","matchCriteriaId":"3B0C1261-B15A-4D91-AC65-9834D16A94F1"}]}]}],"references":[{"url":"https://www.ericsson.com/en/about-us/security/psirt/e2025-09-25","source":"85b1779b-6ecd-4f52-bcc5-73eac4659dcf","tags":["Vendor Advisory"]}]}}]}