{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-09-22T11:55:38.086","vulnerabilities":[{"cve":{"id":"CVE-2025-37185","sourceIdentifier":"security-alert@hpe.com","published":"2026-01-14T17:16:06.437","lastModified":"2026-06-17T09:15:19.323","vulnStatus":"Analyzed","cveTags":[],"descriptions":[{"lang":"en","value":"Vulnerabilities in the web-based management interface of EdgeConnect SD-WAN Orchestrator could allow an authenticated remote attacker to conduct a stored cross-site scripting (XSS) attacks against an administrative user of the interface. A successful exploit allows an attacker to execute arbitrary script code in a victim's browser in the context of the affected interface and thereby make unauthorized arbitrary configuration changes to the host."},{"lang":"es","value":"Vulnerabilidades en la interfaz de gestión basada en web de EdgeConnect SD-WAN Orchestrator podrían permitir a un atacante remoto autenticado realizar ataques de cross-site scripting (XSS) almacenados contra un usuario administrativo de la interfaz. Un exploit exitoso permite a un atacante ejecutar código de script arbitrario en el navegador de una víctima en el contexto de la interfaz afectada y, por lo tanto, realizar cambios de configuración arbitrarios no autorizados en el host."}],"affected":[{"source":"security-alert@hpe.com","affectedData":[{"vendor":"Hewlett Packard Enterprise (HPE)","product":"EdgeConnect SD-WAN Orchestrator","defaultStatus":"affected","versions":[{"version":"9.5.0","lessThanOrEqual":"9.6.0","versionType":"semver","status":"affected"},{"version":"9.4.0","lessThanOrEqual":"9.4.4","versionType":"semver","status":"affected"}]}]}],"metrics":{"cvssMetricV31":[{"source":"security-alert@hpe.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:N","baseScore":5.5,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"HIGH","userInteraction":"NONE","scope":"CHANGED","confidentialityImpact":"LOW","integrityImpact":"LOW","availabilityImpact":"NONE"},"exploitabilityScore":2.3,"impactScore":2.7},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N","baseScore":4.8,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"HIGH","userInteraction":"REQUIRED","scope":"CHANGED","confidentialityImpact":"LOW","integrityImpact":"LOW","availabilityImpact":"NONE"},"exploitabilityScore":1.7,"impactScore":2.7}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"timestamp":"2026-01-14T16:46:59.698567Z","id":"CVE-2025-37185","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}]},"weaknesses":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","type":"Secondary","description":[{"lang":"en","value":"CWE-79"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:arubanetworks:edgeconnect_sd-wan_orchestrator:*:*:*:*:*:*:*:*","versionStartIncluding":"9.2.0","versionEndIncluding":"9.2.10","matchCriteriaId":"4972AD17-B8C3-4E30-B757-0B5BB830B28C"},{"vulnerable":true,"criteria":"cpe:2.3:a:arubanetworks:edgeconnect_sd-wan_orchestrator:*:*:*:*:*:*:*:*","versionStartIncluding":"9.3.0","versionEndIncluding":"9.3.6","matchCriteriaId":"48DA7E3C-5E4C-4A91-872E-F278046A3146"},{"vulnerable":true,"criteria":"cpe:2.3:a:arubanetworks:edgeconnect_sd-wan_orchestrator:*:*:*:*:*:*:*:*","versionStartIncluding":"9.4.0","versionEndIncluding":"9.4.4","matchCriteriaId":"F65E7518-5652-4651-B8B8-25C763044E7B"},{"vulnerable":true,"criteria":"cpe:2.3:a:arubanetworks:edgeconnect_sd-wan_orchestrator:*:*:*:*:*:*:*:*","versionStartIncluding":"9.5.0","versionEndExcluding":"9.5.6","matchCriteriaId":"6C96154A-927C-4F4C-B00E-9E10340859A0"},{"vulnerable":true,"criteria":"cpe:2.3:a:arubanetworks:edgeconnect_sd-wan_orchestrator:9.6.0:*:*:*:*:*:*:*","matchCriteriaId":"B5EBF5C1-4470-40F0-9812-1729E7E42DA0"}]}]}],"references":[{"url":"https://support.hpe.com/hpesc/public/docDisplay?docId=hpesbnw04992en_us&docLocale=en_US","source":"security-alert@hpe.com","tags":["Vendor Advisory"]}]}}]}