{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-17T04:48:30.878","vulnerabilities":[{"cve":{"id":"CVE-2025-36463","sourceIdentifier":"talos-cna@cisco.com","published":"2025-11-17T23:15:53.687","lastModified":"2026-04-15T00:35:42.020","vulnStatus":"Deferred","cveTags":[],"descriptions":[{"lang":"en","value":"Multiple out-of-bounds read and write vulnerabilities exist in the ControlVault WBDI Driver Broadcom Storage Adapter functionality of Dell ControlVault3 prior to 5.15.14.19 and Dell ControlVault3 Plus prior to 6.2.36.47. A specially crafted WinBioControlUnit call can lead to memory corruption. An attacker can issue an api call to trigger this vulnerability. This vulnerability is triggered when submitting a `WinBioControlUnit` call to the StorageAdapter with the ControlCode 4 (`WBIO_USH_ADD_RECORD`) and with an invalid   `SendBufferSize`."}],"metrics":{"cvssMetricV31":[{"source":"talos-cna@cisco.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H","baseScore":7.3,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.3,"impactScore":5.9}]},"weaknesses":[{"source":"talos-cna@cisco.com","type":"Secondary","description":[{"lang":"en","value":"CWE-805"}]}],"references":[{"url":"https://talosintelligence.com/vulnerability_reports/TALOS-2025-2175","source":"talos-cna@cisco.com"},{"url":"https://www.dell.com/support/kbdoc/en-us/000326061/dsa-2025-228","source":"talos-cna@cisco.com"}]}}]}