{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-15T01:37:38.635","vulnerabilities":[{"cve":{"id":"CVE-2025-32838","sourceIdentifier":"productcert@siemens.com","published":"2025-04-16T18:16:11.590","lastModified":"2025-08-19T15:22:55.340","vulnStatus":"Analyzed","cveTags":[],"descriptions":[{"lang":"en","value":"A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'ImportConnectionVariables' method. This could allow an authenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with \"NT AUTHORITY\\NetworkService\" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on."},{"lang":"es","value":"Se ha identificado una vulnerabilidad en TeleControl Server Basic (todas las versiones anteriores a V3.1.2.2). La aplicación afectada es vulnerable a la inyección de SQL mediante el método interno \"ImportConnectionVariables\". Esto podría permitir que un atacante remoto autenticado eluda los controles de autorización, lea y escriba en la base de datos de la aplicación y ejecute código con permisos \"NT AUTHORITY\\NetworkService\". Para que el ataque tenga éxito, el atacante debe poder acceder al puerto 8000 de un sistema donde se ejecute una versión vulnerable de la aplicación afectada."}],"metrics":{"cvssMetricV40":[{"source":"productcert@siemens.com","type":"Secondary","cvssData":{"version":"4.0","vectorString":"CVSS:4.0\/AV:N\/AC:L\/AT:N\/PR:L\/UI:N\/VC:H\/VI:H\/VA:H\/SC:N\/SI:N\/SA:N\/E:X\/CR:X\/IR:X\/AR:X\/MAV:X\/MAC:X\/MAT:X\/MPR:X\/MUI:X\/MVC:X\/MVI:X\/MVA:X\/MSC:X\/MSI:X\/MSA:X\/S:X\/AU:X\/R:X\/V:X\/RE:X\/U:X","baseScore":8.7,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"LOW","userInteraction":"NONE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnAvailabilityImpact":"HIGH","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}}],"cvssMetricV31":[{"source":"productcert@siemens.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1\/AV:N\/AC:L\/PR:L\/UI:N\/S:U\/C:H\/I:H\/A:H","baseScore":8.8,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.8,"impactScore":5.9}]},"weaknesses":[{"source":"productcert@siemens.com","type":"Secondary","description":[{"lang":"en","value":"CWE-89"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:telecontrol_server_basic:*:*:*:*:*:*:*:*","versionEndExcluding":"3.1.2.2","matchCriteriaId":"5A439C0E-7853-489C-93A5-40596265F6D0"}]}]}],"references":[{"url":"https:\/\/cert-portal.siemens.com\/productcert\/html\/ssa-443402.html","source":"productcert@siemens.com","tags":["Vendor Advisory"]}]}}]}