{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-06-13T22:48:29.192","vulnerabilities":[{"cve":{"id":"CVE-2025-31366","sourceIdentifier":"psirt@fortinet.com","published":"2025-10-14T16:15:37.423","lastModified":"2026-06-09T10:16:34.950","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"An Improper Neutralization of Input During Web Page Generation vulnerability [CWE-79] vulnerability in Fortinet FortiOS 7.6.0 through 7.6.3, FortiOS 7.4.0 through 7.4.8, FortiOS 7.2 all versions, FortiOS 7.0 all versions, FortiOS 6.4 all versions, FortiProxy 7.6.0 through 7.6.3, FortiProxy 7.4 all versions, FortiProxy 7.2 all versions, FortiProxy 7.0 all versions, FortiSASE 25.2.a may allow an unauthenticated attacker to perform a reflected cross site scripting (XSS) via crafted HTTP requests."}],"metrics":{"cvssMetricV31":[{"source":"psirt@fortinet.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:L/I:L/A:N","baseScore":4.7,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"HIGH","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"CHANGED","confidentialityImpact":"LOW","integrityImpact":"LOW","availabilityImpact":"NONE"},"exploitabilityScore":1.6,"impactScore":2.7},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N","baseScore":6.1,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"CHANGED","confidentialityImpact":"LOW","integrityImpact":"LOW","availabilityImpact":"NONE"},"exploitabilityScore":2.8,"impactScore":2.7}]},"weaknesses":[{"source":"psirt@fortinet.com","type":"Secondary","description":[{"lang":"en","value":"CWE-79"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:fortinet:fortios:*:*:*:*:*:*:*:*","versionStartIncluding":"6.4.0","versionEndExcluding":"7.4.9","matchCriteriaId":"1B6548FD-E370-45D7-81D5-6EF892810052"},{"vulnerable":true,"criteria":"cpe:2.3:o:fortinet:fortios:*:*:*:*:*:*:*:*","versionStartIncluding":"7.6.0","versionEndExcluding":"7.6.4","matchCriteriaId":"C1C30E0D-7F09-42D2-9EB1-E2196BD50D75"}]}]},{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:fortinet:fortiproxy:*:*:*:*:*:*:*:*","versionStartIncluding":"7.0.0","versionEndExcluding":"7.6.4","matchCriteriaId":"4DA70753-E996-4081-9C13-7F60AC993B09"}]}]},{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:fortinet:fortisase:25.3.40:*:*:*:feature:*:*:*","matchCriteriaId":"53197A72-5D08-4938-A415-72C573024BF3"},{"vulnerable":true,"criteria":"cpe:2.3:a:fortinet:fortisase:25.3.40:*:*:*:mature:*:*:*","matchCriteriaId":"2603C391-AEC6-450A-A30A-4F8682F9565D"}]}]}],"references":[{"url":"https://fortiguard.fortinet.com/psirt/FG-IR-24-542","source":"psirt@fortinet.com","tags":["Vendor Advisory"]},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-864900.html","source":"0b142b55-0307-4c5a-b3c9-f314f3fb7c5e"}]}}]}