{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-15T18:52:21.052582900Z","vulnerabilities":[{"cve":{"id":"CVE-2025-25250","sourceIdentifier":"psirt@fortinet.com","published":"2025-06-10T17:21:16.550","lastModified":"2025-07-22T17:52:45.433","vulnStatus":"Analyzed","cveTags":[],"descriptions":[{"lang":"en","value":"An Exposure of Sensitive Information to an Unauthorized Actor vulnerability [CWE-200] in FortiOS version 7.6.0, version 7.4.7 and below, 7.2 all versions, 7.0 all versions, 6.4 all versions SSL-VPN web-mode may allow an authenticated user to access full SSL-VPN settings via crafted URL."},{"lang":"es","value":"Una vulnerabilidad de exposición de información confidencial a un actor no autorizado [CWE-200] en FortiOS versión 7.6.0, versión 7.4.7 y anteriores, 7.2 todas las versiones, 7.0 todas las versiones, 6.4 todas las versiones. El modo web de SSL-VPN puede permitir que un usuario autenticado acceda a la configuración completa de SSL-VPN a través de una URL manipulada."}],"metrics":{"cvssMetricV31":[{"source":"psirt@fortinet.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N","baseScore":4.3,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"LOW","integrityImpact":"NONE","availabilityImpact":"NONE"},"exploitabilityScore":2.8,"impactScore":1.4},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N","baseScore":4.3,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"LOW","integrityImpact":"NONE","availabilityImpact":"NONE"},"exploitabilityScore":2.8,"impactScore":1.4}]},"weaknesses":[{"source":"psirt@fortinet.com","type":"Secondary","description":[{"lang":"en","value":"CWE-200"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:fortinet:fortisase:25.1.75:*:*:*:-:*:*:*","matchCriteriaId":"ABDA3F6A-4983-404C-BAEF-9D86C635E722"},{"vulnerable":true,"criteria":"cpe:2.3:o:fortinet:fortios:*:*:*:*:*:*:*:*","versionStartIncluding":"6.4.0","versionEndExcluding":"7.4.8","matchCriteriaId":"2B680FFD-D548-4E53-877F-71E72C99E25E"},{"vulnerable":true,"criteria":"cpe:2.3:o:fortinet:fortios:7.6.0:*:*:*:*:*:*:*","matchCriteriaId":"44CE8EE3-D64A-49C8-87D7-C18B302F864A"}]}]}],"references":[{"url":"https://fortiguard.fortinet.com/psirt/FG-IR-24-257","source":"psirt@fortinet.com","tags":["Vendor Advisory"]}]}}]}