{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-06-02T04:29:28.517","vulnerabilities":[{"cve":{"id":"CVE-2025-24477","sourceIdentifier":"psirt@fortinet.com","published":"2025-07-15T09:15:22.267","lastModified":"2026-02-10T08:15:55.963","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"A heap-based buffer overflow vulnerability in Fortinet FortiOS 7.6.0 through 7.6.2, FortiOS 7.4.0 through 7.4.7, FortiOS 7.2.4 through 7.2.12 allows an attacker to escalate its privileges via a specially crafted CLI command"},{"lang":"es","value":"Un desbordamiento de búfer basado en montón en las versiones 7.6.0 a 7.6.2, 7.4.0 a 7.4.7 y 7.2.4 a 7.2.11 de Fortinet FortiOS permite a un atacante escalar sus privilegios a través de un comando CLI especialmente manipulado."}],"metrics":{"cvssMetricV31":[{"source":"psirt@fortinet.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L","baseScore":4.2,"baseSeverity":"MEDIUM","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"HIGH","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"LOW","integrityImpact":"LOW","availabilityImpact":"LOW"},"exploitabilityScore":0.8,"impactScore":3.4},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","baseScore":6.7,"baseSeverity":"MEDIUM","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"HIGH","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":0.8,"impactScore":5.9}]},"weaknesses":[{"source":"psirt@fortinet.com","type":"Secondary","description":[{"lang":"en","value":"CWE-122"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:fortinet:fortios:*:*:*:*:*:*:*:*","versionStartIncluding":"7.2.4","versionEndExcluding":"7.2.12","matchCriteriaId":"9983FD26-F4F7-43AE-9015-4A83F0A6E238"},{"vulnerable":true,"criteria":"cpe:2.3:o:fortinet:fortios:*:*:*:*:*:*:*:*","versionStartIncluding":"7.4.0","versionEndExcluding":"7.4.8","matchCriteriaId":"26515743-5A9A-4885-A08E-535E4ABE0153"},{"vulnerable":true,"criteria":"cpe:2.3:o:fortinet:fortios:*:*:*:*:*:*:*:*","versionStartIncluding":"7.6.0","versionEndExcluding":"7.6.3","matchCriteriaId":"D6B883B9-9ECD-4BC5-B497-770F34F92473"}]}]}],"references":[{"url":"https://fortiguard.fortinet.com/psirt/FG-IR-25-026","source":"psirt@fortinet.com","tags":["Vendor Advisory"]}]}}]}