{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-18T17:31:11.178","vulnerabilities":[{"cve":{"id":"CVE-2025-23376","sourceIdentifier":"security_alert@emc.com","published":"2025-04-28T15:15:45.303","lastModified":"2025-05-13T13:25:04.360","vulnStatus":"Analyzed","cveTags":[],"descriptions":[{"lang":"en","value":"Dell PowerProtect Data Manager Reporting, version(s) 19.16, 19.17, 19.18, contain(s) an Improper Neutralization of Special Elements Used in a Template Engine vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to information disclosure."},{"lang":"es","value":"Dell PowerProtect Data Manager Reporting, versiones 19.16, 19.17 y 19.18, contiene una vulnerabilidad de neutralización incorrecta de elementos especiales utilizados en un motor de plantillas. Un atacante con privilegios elevados y acceso local podría explotar esta vulnerabilidad, lo que podría provocar la divulgación de información."}],"metrics":{"cvssMetricV31":[{"source":"security_alert@emc.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:L/I:N/A:N","baseScore":2.3,"baseSeverity":"LOW","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"HIGH","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"LOW","integrityImpact":"NONE","availabilityImpact":"NONE"},"exploitabilityScore":0.8,"impactScore":1.4},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N","baseScore":4.4,"baseSeverity":"MEDIUM","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"HIGH","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"NONE","availabilityImpact":"NONE"},"exploitabilityScore":0.8,"impactScore":3.6}]},"weaknesses":[{"source":"security_alert@emc.com","type":"Secondary","description":[{"lang":"en","value":"CWE-1336"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-94"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:dell:powerprotect_data_manager:19.16:*:*:*:*:*:*:*","matchCriteriaId":"A2E6C20D-C6CA-4789-B786-B7847C77D3A6"},{"vulnerable":true,"criteria":"cpe:2.3:a:dell:powerprotect_data_manager:19.17:*:*:*:*:*:*:*","matchCriteriaId":"2BF4BC3A-FED6-4628-82A4-AD5440917800"},{"vulnerable":true,"criteria":"cpe:2.3:a:dell:powerprotect_data_manager:19.18:*:*:*:*:*:*:*","matchCriteriaId":"5E142B7E-4B84-45D1-87FC-521EEA20187E"}]}]}],"references":[{"url":"https://www.dell.com/support/kbdoc/en-us/000311083/dsa-2025-062-security-update-for-dell-powerprotect-data-manager-multiple-security-vulnerabilities","source":"security_alert@emc.com","tags":["Vendor Advisory"]}]}}]}