{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-17T15:25:16.089","vulnerabilities":[{"cve":{"id":"CVE-2025-20684","sourceIdentifier":"security@mediatek.com","published":"2025-07-08T03:15:27.690","lastModified":"2025-07-09T17:24:01.167","vulnStatus":"Analyzed","cveTags":[],"descriptions":[{"lang":"en","value":"In wlan AP driver, there is a possible out of bounds write due to an incorrect bounds check. This could lead to local escalation of privilege with User execution privileges needed. User interaction is not needed for exploitation. Patch ID: WCNCR00416939; Issue ID: MSV-3422."},{"lang":"es","value":"En el controlador del punto de acceso WLAN, existe una posible escritura fuera de los límites debido a una comprobación incorrecta de los límites. Esto podría provocar una escalada local de privilegios, requiriendo privilegios de ejecución del usuario. No se requiere la interacción del usuario para la explotación. ID de parche: WCNCR00416939; ID de problema: MSV-3422."}],"metrics":{"cvssMetricV31":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":9.8,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":5.9}]},"weaknesses":[{"source":"security@mediatek.com","type":"Secondary","description":[{"lang":"en","value":"CWE-787"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:mediatek:software_development_kit:*:*:*:*:*:*:*:*","versionEndIncluding":"5.1.0.0","matchCriteriaId":"B79B741E-4926-404D-AB0C-01E605332129"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:mediatek:mt7615:-:*:*:*:*:*:*:*","matchCriteriaId":"05748BB1-0D48-4097-932E-E8E2E574FD8D"},{"vulnerable":false,"criteria":"cpe:2.3:h:mediatek:mt7622:-:*:*:*:*:*:*:*","matchCriteriaId":"55EB4B27-6264-45BE-9A22-BE8418BB0C06"},{"vulnerable":false,"criteria":"cpe:2.3:h:mediatek:mt7663:-:*:*:*:*:*:*:*","matchCriteriaId":"10C79211-F064-499D-914E-0BACD038FBF4"}]}]}],"references":[{"url":"https://corp.mediatek.com/product-security-bulletin/July-2025","source":"security@mediatek.com","tags":["Vendor Advisory"]}]}}]}