{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-06-11T13:59:03.065","vulnerabilities":[{"cve":{"id":"CVE-2025-13957","sourceIdentifier":"cybersecurity@se.com","published":"2026-03-10T18:17:52.377","lastModified":"2026-03-11T13:53:47.157","vulnStatus":"Awaiting Analysis","cveTags":[],"descriptions":[{"lang":"en","value":"CWE-798: Use of Hard-coded Credentials vulnerability exists that could cause information disclosure and remote code execution when SOCKS Proxy is enabled, and administrator credentials and PostgreSQL database credentials are known. SOCKS Proxy is disabled by default."},{"lang":"es","value":"CWE-798: Existe una vulnerabilidad de uso de credenciales codificadas que podría causar revelación de información y ejecución remota de código cuando el proxy SOCKS está habilitado, y las credenciales de administrador y las credenciales de la base de datos PostgreSQL son conocidas. El proxy SOCKS está deshabilitado por defecto."}],"metrics":{"cvssMetricV40":[{"source":"cybersecurity@se.com","type":"Secondary","cvssData":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:L/AT:P/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":7.5,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","attackRequirements":"PRESENT","privilegesRequired":"HIGH","userInteraction":"NONE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnAvailabilityImpact":"HIGH","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}}]},"weaknesses":[{"source":"cybersecurity@se.com","type":"Primary","description":[{"lang":"en","value":"CWE-798"}]}],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2026-069-05&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2026-069-05.pdf","source":"cybersecurity@se.com"}]}}]}