{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-17T09:49:44.360","vulnerabilities":[{"cve":{"id":"CVE-2025-11780","sourceIdentifier":"cve-coordination@incibe.es","published":"2025-12-02T13:15:48.887","lastModified":"2025-12-03T19:08:11.750","vulnStatus":"Analyzed","cveTags":[{"sourceIdentifier":"cve-coordination@incibe.es","tags":["unsupported-when-assigned"]}],"descriptions":[{"lang":"en","value":"Stack-based buffer overflow vulnerability in Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. In the 'showMeterReport()' function, there is an unlimited user input that is copied to a fixed-size buffer via 'sprintf()'. The 'GetParameter(meter)' function retrieves the user input, which is directly incorporated into a buffer without size validation. An attacker can provide an excessively large input for the “meter” parameter."},{"lang":"es","value":"Vulnerabilidad de desbordamiento de búfer basado en pila en Circutor SGE-PLC1000/SGE-PLC50 v9.0.2. En la función 'showMeterReport()', existe una entrada de usuario ilimitada que se copia a un búfer de tamaño fijo a través de 'sprintf()'. La función 'GetParameter(meter)' recupera la entrada del usuario, la cual se incorpora directamente a un búfer sin validación de tamaño. Un atacante puede proporcionar una entrada excesivamente grande para el parámetro 'meter'."}],"metrics":{"cvssMetricV40":[{"source":"cve-coordination@incibe.es","type":"Secondary","cvssData":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":8.7,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"LOW","userInteraction":"NONE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnAvailabilityImpact":"HIGH","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}}],"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":9.8,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":5.9}]},"weaknesses":[{"source":"cve-coordination@incibe.es","type":"Secondary","description":[{"lang":"en","value":"CWE-120"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:circutor:sge-plc1000_firmware:9.0.2:*:*:*:*:*:*:*","matchCriteriaId":"3FC715A9-6F95-4795-B3B1-1BFAF88ACCE9"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:circutor:sge-plc1000:-:*:*:*:*:*:*:*","matchCriteriaId":"FFF41215-1018-42DD-9A7E-BBC2E5B4522D"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:circutor:sge-plc50_firmware:9.0.2:*:*:*:*:*:*:*","matchCriteriaId":"203C8B5E-582A-4680-B324-B9092F01462B"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:circutor:sge-plc50:-:*:*:*:*:*:*:*","matchCriteriaId":"447D1571-5329-422D-8E31-F4964E412FC3"}]}]}],"references":[{"url":"https://www.incibe.es/en/incibe-cert/notices/aviso-sci/multiple-vulnerabilities-circutor-products-0","source":"cve-coordination@incibe.es","tags":["Third Party Advisory"]}]}}]}