{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-20T01:36:16.957","vulnerabilities":[{"cve":{"id":"CVE-2025-0327","sourceIdentifier":"cybersecurity@se.com","published":"2025-02-13T07:15:10.570","lastModified":"2026-04-15T00:35:42.020","vulnStatus":"Deferred","cveTags":[],"descriptions":[{"lang":"en","value":"CWE-269: Improper Privilege Management vulnerability exists for two services (of which one managing audit\ntrail data and the other acting as server managing client request) that could cause a loss of Confidentiality,\nIntegrity and Availability of engineering workstation when an attacker with standard privilege modifies the\nexecutable path of the windows services. To be exploited, services need to be restarted."},{"lang":"es","value":"CWE-269: Existe una vulnerabilidad de administración inadecuada de privilegios para dos servicios (uno de los cuales administra los datos de registro de auditoría y el otro actúa como servidor que administra las solicitudes de los clientes) que podría provocar una pérdida de confidencialidad, integridad y disponibilidad de la estación de trabajo de ingeniería cuando un atacante con privilegios estándar modifica la ruta ejecutable de los servicios de Windows. Para explotarla, es necesario reiniciar los servicios."}],"metrics":{"cvssMetricV40":[{"source":"cybersecurity@se.com","type":"Secondary","cvssData":{"version":"4.0","vectorString":"CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":8.5,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"LOW","userInteraction":"NONE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnAvailabilityImpact":"HIGH","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}}],"cvssMetricV31":[{"source":"cybersecurity@se.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9}]},"weaknesses":[{"source":"cybersecurity@se.com","type":"Secondary","description":[{"lang":"en","value":"CWE-269"}]}],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2025-042-03&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2025-042-03.pdf","source":"cybersecurity@se.com"}]}}]}