{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-27T16:23:33.742","vulnerabilities":[{"cve":{"id":"CVE-2024-9409","sourceIdentifier":"cybersecurity@se.com","published":"2024-11-13T05:15:27.610","lastModified":"2024-11-19T15:59:21.690","vulnStatus":"Analyzed","cveTags":[],"descriptions":[{"lang":"en","value":"CWE-400: An Uncontrolled Resource Consumption vulnerability exists that could cause the device to become\nunresponsive resulting in communication loss when a large amount of IGMP packets is present in the network."},{"lang":"es","value":"CWE-400: Existe una vulnerabilidad de consumo descontrolado de recursos que podría provocar que el dispositivo deje de responder y produzca pérdida de comunicación cuando hay una gran cantidad de paquetes IGMP en la red."}],"metrics":{"cvssMetricV40":[{"source":"cybersecurity@se.com","type":"Secondary","cvssData":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":8.7,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"NONE","userInteraction":"NONE","vulnConfidentialityImpact":"NONE","vulnIntegrityImpact":"NONE","vulnAvailabilityImpact":"HIGH","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}}],"cvssMetricV31":[{"source":"cybersecurity@se.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","baseScore":7.5,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":3.6},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","baseScore":7.5,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":3.6}]},"weaknesses":[{"source":"cybersecurity@se.com","type":"Secondary","description":[{"lang":"en","value":"CWE-400"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:powerlogic_pm5341_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"2.7.0","matchCriteriaId":"2C518E91-E251-4278-83D6-144B1CC6331F"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:powerlogic_pm5341:-:*:*:*:*:*:*:*","matchCriteriaId":"9C575247-0AE3-408C-8154-71A256FD0292"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:powerlogic_pm5340_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"2.4.0","matchCriteriaId":"65E456CF-4247-4FB9-858D-6920EF946CF2"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:powerlogic_pm5340:-:*:*:*:*:*:*:*","matchCriteriaId":"F5C8EA2A-37CF-435F-A1ED-789255404CD6"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:powerlogic_pm5320_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"2.4.0","matchCriteriaId":"EB64AE9B-637D-48A5-AE98-6F120C7E355A"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:powerlogic_pm5320:-:*:*:*:*:*:*:*","matchCriteriaId":"47592B0C-9E15-4D4C-B284-F2390678E1AC"}]}]}],"references":[{"url":"https://download.schneider-electric.com/doc/SEVD-2024-317-01/SEVD-2024-317-01.pdf","source":"cybersecurity@se.com","tags":["Mitigation","Patch","Vendor Advisory"]}]}}]}