{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-05-02T13:52:48.626","vulnerabilities":[{"cve":{"id":"CVE-2024-9124","sourceIdentifier":"PSIRT@rockwellautomation.com","published":"2024-10-08T17:15:56.390","lastModified":"2025-09-22T18:34:28.750","vulnStatus":"Analyzed","cveTags":[],"descriptions":[{"lang":"en","value":"A denial-of-service vulnerability exists in the Rockwell Automation PowerFlex® 600T. If the device is overloaded with requests, it will become unavailable. The device may require a power cycle to recover it if it does not re-establish a connection after it stops receiving requests."},{"lang":"es","value":"Existe una vulnerabilidad de denegación de servicio en el PowerFlex® 600T de Rockwell Automation. Si el dispositivo se sobrecarga con solicitudes, dejará de estar disponible. Es posible que sea necesario apagar y encender el dispositivo para recuperarlo si no restablece una conexión después de dejar de recibir solicitudes."}],"metrics":{"cvssMetricV40":[{"source":"PSIRT@rockwellautomation.com","type":"Secondary","cvssData":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":8.2,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","attackRequirements":"PRESENT","privilegesRequired":"NONE","userInteraction":"NONE","vulnConfidentialityImpact":"NONE","vulnIntegrityImpact":"NONE","vulnAvailabilityImpact":"HIGH","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}}],"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","baseScore":7.5,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":3.6}]},"weaknesses":[{"source":"PSIRT@rockwellautomation.com","type":"Secondary","description":[{"lang":"en","value":"CWE-754"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:rockwellautomation:powerflex_6000t_firmware:8.001:*:*:*:*:*:*:*","matchCriteriaId":"B94C1B74-BCEF-4F22-8F49-18FABE6E8384"},{"vulnerable":true,"criteria":"cpe:2.3:o:rockwellautomation:powerflex_6000t_firmware:8.002:*:*:*:*:*:*:*","matchCriteriaId":"9CEF373D-896D-4C79-A040-EA265511B70D"},{"vulnerable":true,"criteria":"cpe:2.3:o:rockwellautomation:powerflex_6000t_firmware:9.001:*:*:*:*:*:*:*","matchCriteriaId":"E9BB211E-D2C8-4AC0-9E30-FBDD91CFA4BC"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:rockwellautomation:powerflex_6000t:-:*:*:*:*:*:*:*","matchCriteriaId":"B17F62E5-613F-4D1F-B30B-90110F555814"}]}]}],"references":[{"url":"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1705.html","source":"PSIRT@rockwellautomation.com","tags":["Vendor Advisory"]}]}}]}