{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-09-30T16:13:13.999","vulnerabilities":[{"cve":{"id":"CVE-2024-8441","sourceIdentifier":"3c1d8aa1-5a33-4ea4-8992-aadd6440af75","published":"2024-09-10T21:15:15.613","lastModified":"2026-06-17T08:22:34.897","vulnStatus":"Analyzed","cveTags":[],"descriptions":[{"lang":"en","value":"An uncontrolled search path in the agent of Ivanti EPM before 2022 SU6, or the 2024 September update allows a local authenticated attacker with admin privileges to escalate their privileges to SYSTEM."},{"lang":"es","value":"Una ruta de búsqueda no controlada en el agente de Ivanti EPM antes de 2022 SU6 o la actualización de septiembre de 2024 permite que un atacante autenticado local con privilegios de administrador escale sus permisos a SYSTEM."}],"affected":[{"source":"3c1d8aa1-5a33-4ea4-8992-aadd6440af75","affectedData":[{"vendor":"Ivanti","product":"Endpoint Manager","defaultStatus":"affected","versions":[{"version":"2022 SU6","versionType":"custom","status":"unaffected"},{"version":"2024 September Security Update","versionType":"custom","status":"unaffected"}]}]},{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","affectedData":[{"vendor":"ivanti","product":"endpoint_manager","defaultStatus":"unknown","cpes":["cpe:2.3:a:ivanti:endpoint_manager:*:*:*:*:*:*:*:*"],"versions":[{"version":"0","lessThan":"2022_su6","versionType":"custom","status":"affected"},{"version":"2024_september_update","status":"affected"}]}]}],"metrics":{"cvssMetricV31":[{"source":"3c1d8aa1-5a33-4ea4-8992-aadd6440af75","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","baseScore":6.7,"baseSeverity":"MEDIUM","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"HIGH","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":0.8,"impactScore":5.9},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H","baseScore":6.7,"baseSeverity":"MEDIUM","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"HIGH","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":0.8,"impactScore":5.9}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"timestamp":"2024-09-11T00:00:00+00:00","id":"CVE-2024-8441","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}]},"weaknesses":[{"source":"3c1d8aa1-5a33-4ea4-8992-aadd6440af75","type":"Secondary","description":[{"lang":"en","value":"CWE-427"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-427"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:ivanti:endpoint_manager:*:*:*:*:*:*:*:*","versionEndExcluding":"2022","matchCriteriaId":"B1F6549B-CF5D-4607-B67D-5489905A1705"},{"vulnerable":true,"criteria":"cpe:2.3:a:ivanti:endpoint_manager:2022:-:*:*:*:*:*:*","matchCriteriaId":"46580865-5177-4E55-BDAC-73DA4B472B35"},{"vulnerable":true,"criteria":"cpe:2.3:a:ivanti:endpoint_manager:2022:su1:*:*:*:*:*:*","matchCriteriaId":"E57E12B5-B789-450C-9476-6C4C151E6993"},{"vulnerable":true,"criteria":"cpe:2.3:a:ivanti:endpoint_manager:2022:su2:*:*:*:*:*:*","matchCriteriaId":"E47C65B3-56DD-4D65-8B4B-6AFFE28E94F2"},{"vulnerable":true,"criteria":"cpe:2.3:a:ivanti:endpoint_manager:2022:su3:*:*:*:*:*:*","matchCriteriaId":"10D6EAB7-B14B-45E9-92B9-4FADFBBB08AF"},{"vulnerable":true,"criteria":"cpe:2.3:a:ivanti:endpoint_manager:2022:su4:*:*:*:*:*:*","matchCriteriaId":"1877FB55-76BA-4714-ABB8-47258132F537"},{"vulnerable":true,"criteria":"cpe:2.3:a:ivanti:endpoint_manager:2022:su5:*:*:*:*:*:*","matchCriteriaId":"4F9E8D45-5F12-4D45-A74E-C314FA3618A3"},{"vulnerable":true,"criteria":"cpe:2.3:a:ivanti:endpoint_manager:2024:-:*:*:*:*:*:*","matchCriteriaId":"6C7283FE-C10A-4E37-B004-15FB0CAC49A5"}]}]}],"references":[{"url":"https://forums.ivanti.com/s/article/Security-Advisory-EPM-September-2024-for-EPM-2024-and-EPM-2022","source":"3c1d8aa1-5a33-4ea4-8992-aadd6440af75","tags":["Vendor Advisory"]}]}}]}