{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-18T14:54:30.865","vulnerabilities":[{"cve":{"id":"CVE-2024-8306","sourceIdentifier":"cybersecurity@se.com","published":"2024-09-11T15:15:18.827","lastModified":"2024-09-18T19:51:14.850","vulnStatus":"Analyzed","cveTags":[],"descriptions":[{"lang":"en","value":"CWE-269: Improper Privilege Management vulnerability exists that could cause unauthorized\naccess, loss of confidentiality, integrity and availability of the workstation when non-admin\nauthenticated user tries to perform privilege escalation by tampering with the binaries."},{"lang":"es","value":"CWE-269: Existe una vulnerabilidad de administración inadecuada de privilegios que podría causar acceso no autorizado, pérdida de confidencialidad, integridad y disponibilidad de la estación de trabajo cuando un usuario autenticado que no es administrador intenta realizar una escalada de privilegios alterando los binarios."}],"metrics":{"cvssMetricV31":[{"source":"cybersecurity@se.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9}]},"weaknesses":[{"source":"cybersecurity@se.com","type":"Secondary","description":[{"lang":"en","value":"CWE-269"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"NVD-CWE-noinfo"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:vijeo_designer:*:*:*:*:*:*:*:*","versionEndExcluding":"6.3","matchCriteriaId":"F4501EC7-939C-4E71-A5D3-3F1112D39190"},{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:vijeo_designer:6.3:-:*:*:*:*:*:*","matchCriteriaId":"204A592B-1B28-43FC-878F-559BDF5A7944"},{"vulnerable":true,"criteria":"cpe:2.3:a:schneider-electric:vijeo_designer_embedded_in_ecostruxure_machine_expert:*:*:*:*:*:*:*:*","matchCriteriaId":"99EBBD6F-0C97-493A-B708-60DD27733247"}]}]}],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-254-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-254-01.pdf","source":"cybersecurity@se.com","tags":["Vendor Advisory"]}]}}]}