{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-19T06:46:54.272","vulnerabilities":[{"cve":{"id":"CVE-2024-7507","sourceIdentifier":"PSIRT@rockwellautomation.com","published":"2024-08-14T20:15:12.900","lastModified":"2025-03-04T17:45:08.957","vulnStatus":"Analyzed","cveTags":[],"descriptions":[{"lang":"en","value":"CVE-2024-7507 IMPACT\n\nA denial-of-service vulnerability exists in the affected products.  This vulnerability occurs when a malformed PCCC message is received, causing a fault in the controller."},{"lang":"es","value":" CVE-2024-7507 IMPACT Existe una vulnerabilidad de denegación de servicio en los productos afectados. Esta vulnerabilidad ocurre cuando se recibe un mensaje PCCC con formato incorrecto, lo que provoca un fallo en el controlador."}],"metrics":{"cvssMetricV40":[{"source":"PSIRT@rockwellautomation.com","type":"Secondary","cvssData":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":8.7,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"NONE","userInteraction":"NONE","vulnConfidentialityImpact":"NONE","vulnIntegrityImpact":"NONE","vulnAvailabilityImpact":"HIGH","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}}],"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H","baseScore":6.5,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH"},"exploitabilityScore":2.8,"impactScore":3.6}]},"weaknesses":[{"source":"PSIRT@rockwellautomation.com","type":"Secondary","description":[{"lang":"en","value":"CWE-20"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"NVD-CWE-noinfo"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:rockwellautomation:compactlogix_5380_firmware:*:*:*:*:*:*:*:*","versionStartIncluding":"28.011","versionEndExcluding":"34.014","matchCriteriaId":"AABBF4EF-9F0E-432D-A535-F74402CFD05D"},{"vulnerable":true,"criteria":"cpe:2.3:o:rockwellautomation:compactlogix_5380_firmware:35.011:*:*:*:*:*:*:*","matchCriteriaId":"305CDBFF-404A-45F5-A391-1B18F446D1B8"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:rockwellautomation:compactlogix_5380:-:*:*:*:*:*:*:*","matchCriteriaId":"EDD040ED-B44C-47D0-B4D4-729C378C4F68"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:rockwellautomation:controllogix_5580_firmware:*:*:*:*:*:*:*:*","versionStartIncluding":"28.011","versionEndExcluding":"34.014","matchCriteriaId":"E5B18F7F-80AB-4146-9D65-B1DB4C2FAA8D"},{"vulnerable":true,"criteria":"cpe:2.3:o:rockwellautomation:controllogix_5580_firmware:35.011:*:*:*:*:*:*:*","matchCriteriaId":"A29D3775-CAB3-45CF-96CE-71D0672C7E37"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:rockwellautomation:controllogix_5580:-:*:*:*:*:*:*:*","matchCriteriaId":"51BB883B-B863-4D57-B1C0-FC7B3EBD1EA0"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:rockwellautomation:guardlogix_5580_firmware:*:*:*:*:*:*:*:*","versionStartIncluding":"31.011","versionEndExcluding":"34.014","matchCriteriaId":"CC2E9A2F-AFC7-442D-88FC-C3217ABB560E"},{"vulnerable":true,"criteria":"cpe:2.3:o:rockwellautomation:guardlogix_5580_firmware:35.011:*:*:*:*:*:*:*","matchCriteriaId":"64CAC9B1-19E5-44BB-B814-DDA98B7290E4"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:rockwellautomation:guardlogix_5580:-:*:*:*:*:*:*:*","matchCriteriaId":"006B7683-9FDF-4748-BA28-2EA22613E092"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:rockwellautomation:compact_guardlogix_5380_sil_2_firmware:*:*:*:*:*:*:*:*","versionStartIncluding":"31.011","versionEndExcluding":"34.014","matchCriteriaId":"560A9F50-DBCF-48CF-856B-BE061C490697"},{"vulnerable":true,"criteria":"cpe:2.3:o:rockwellautomation:compact_guardlogix_5380_sil_2_firmware:35.011:*:*:*:*:*:*:*","matchCriteriaId":"F7A5DA9B-E1CA-45FF-8A9B-60B1E506F981"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:rockwellautomation:compact_guardlogix_5380_sil_2:-:*:*:*:*:*:*:*","matchCriteriaId":"E594CDF6-0582-4D5C-B6AA-C8A2E752E29F"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:rockwellautomation:compact_guardlogix_5380_sil_3_firmware:*:*:*:*:*:*:*:*","versionStartIncluding":"32.013","versionEndExcluding":"34.014","matchCriteriaId":"3631A2E0-00BA-4DF2-94C2-6906B9A3E941"},{"vulnerable":true,"criteria":"cpe:2.3:o:rockwellautomation:compact_guardlogix_5380_sil_3_firmware:35.011:*:*:*:*:*:*:*","matchCriteriaId":"ABE90277-EB8A-4ECE-A573-C1814F35CB47"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:rockwellautomation:compact_guardlogix_5380_sil_3:-:*:*:*:*:*:*:*","matchCriteriaId":"B82D842C-0930-41AA-83CD-5F235771AE4B"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:rockwellautomation:compactlogix_5480_firmware:*:*:*:*:*:*:*:*","versionStartIncluding":"32.011","versionEndExcluding":"34.014","matchCriteriaId":"8C025589-66EE-40EF-8CE6-9A7B76D74BF4"},{"vulnerable":true,"criteria":"cpe:2.3:o:rockwellautomation:compactlogix_5480_firmware:35.011:*:*:*:*:*:*:*","matchCriteriaId":"61F8EA3B-C51C-4CB1-9BB3-017577DC6684"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:rockwellautomation:compactlogix_5480:-:*:*:*:*:*:*:*","matchCriteriaId":"80F4F5BE-07DF-402A-BF98-34FBA6A11968"}]}]}],"references":[{"url":"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD%201685.html","source":"PSIRT@rockwellautomation.com","tags":["Vendor Advisory"]}]}}]}