{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-17T18:53:37.682","vulnerabilities":[{"cve":{"id":"CVE-2024-6528","sourceIdentifier":"cybersecurity@se.com","published":"2024-07-11T09:15:04.867","lastModified":"2024-11-21T09:49:48.730","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site\nScripting') vulnerability exists that could cause a vulnerability leading to a cross-site scripting\ncondition where attackers can have a victim’s browser run arbitrary JavaScript when they visit a\npage containing the injected payload."},{"lang":"es","value":"CWE-79: Existe una vulnerabilidad de neutralización incorrecta de la entrada durante la generación de páginas web (\"Cross-site Scripting\") que podría causar una vulnerabilidad que conduzca a una condición de cross-site scripting donde los atacantes pueden hacer que el navegador de la víctima ejecute JavaScript arbitrario cuando visitan una página que contiene el payload inyectado."}],"metrics":{"cvssMetricV31":[{"source":"cybersecurity@se.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N","baseScore":5.4,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"REQUIRED","scope":"CHANGED","confidentialityImpact":"LOW","integrityImpact":"LOW","availabilityImpact":"NONE"},"exploitabilityScore":2.3,"impactScore":2.7},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N","baseScore":6.1,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"CHANGED","confidentialityImpact":"LOW","integrityImpact":"LOW","availabilityImpact":"NONE"},"exploitabilityScore":2.8,"impactScore":2.7}]},"weaknesses":[{"source":"cybersecurity@se.com","type":"Secondary","description":[{"lang":"en","value":"CWE-79"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:modicon_m241_firmware:*:*:*:*:*:*:*:*","matchCriteriaId":"363D8E9E-0169-472F-A891-EF2E7D329EA2"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:modicon_m241:-:*:*:*:*:*:*:*","matchCriteriaId":"4D8FD9D9-F59F-470E-9F7F-CDDD80B0633C"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:modicon_m251_firmware:*:*:*:*:*:*:*:*","matchCriteriaId":"FB11232E-0DC2-436F-985A-94BCE6A4F6D4"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:modicon_m251:-:*:*:*:*:*:*:*","matchCriteriaId":"B8E03A25-B0B6-4BA2-80BC-52C16A6837E0"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:modicon_m258_firmware:*:*:*:*:*:*:*:*","matchCriteriaId":"686716B7-1C82-483C-A62F-A33F7C5BF32F"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:modicon_m258:-:*:*:*:*:*:*:*","matchCriteriaId":"FFBF6514-3E32-4C8E-81BA-D6464824351F"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:modicon_m262_firmware:*:*:*:*:*:*:*:*","matchCriteriaId":"95E522F5-019E-4948-86D3-B436EEFBAA67"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:modicon_m262:-:*:*:*:*:*:*:*","matchCriteriaId":"F2C151DF-D716-4F2F-8129-9D1B88430A72"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:modicon_lmc058_firmware:*:*:*:*:*:*:*:*","matchCriteriaId":"3B05FDCA-D7FB-4931-B058-377B20E1BB1A"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:modicon_lmc058:-:*:*:*:*:*:*:*","matchCriteriaId":"0DFCD3D7-B85B-4C9E-B80C-B83B017183AA"}]}]}],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-191-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-191-04.pdf","source":"cybersecurity@se.com","tags":["Vendor Advisory"]},{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-191-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-191-04.pdf","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}