{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-06-25T16:19:23.247","vulnerabilities":[{"cve":{"id":"CVE-2024-57580","sourceIdentifier":"cve@mitre.org","published":"2025-01-16T21:15:17.223","lastModified":"2026-06-17T08:13:43.213","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"Tenda AC18 V15.03.05.19 was discovered to contain a stack overflow via the devName parameter in the formSetDeviceName function."},{"lang":"es","value":"Se descubrió que Tenda AC18 V15.03.05.19 contiene un desbordamiento de pila a través del parámetro devName en la función formSetDeviceName."}],"affected":[{"source":"cve@mitre.org","affectedData":[{"vendor":"n/a","product":"n/a","versions":[{"version":"n/a","status":"affected"}]}]}],"metrics":{"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":9.8,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":5.9},{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H","baseScore":9.8,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":3.9,"impactScore":5.9}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"timestamp":"2025-01-17T17:03:11.485108Z","id":"CVE-2024-57580","options":[{"exploitation":"poc"},{"automatable":"yes"},{"technicalImpact":"total"}],"role":"CISA Coordinator","version":"2.0.3"}}]},"weaknesses":[{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-787"}]},{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","type":"Secondary","description":[{"lang":"en","value":"CWE-787"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:tenda:ac18_firmware:15.03.05.19:*:*:*:*:*:*:*","matchCriteriaId":"BA3A313A-5085-4ABB-92D0-A26208EE44FB"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:tenda:ac18:-:*:*:*:*:*:*:*","matchCriteriaId":"CF9F8AF9-F921-4348-922B-EE5E6037E7AC"}]}]}],"references":[{"url":"https://github.com/qijiale/Tenda/tree/main/7","source":"cve@mitre.org","tags":["Exploit","Third Party Advisory"]}]}}]}