{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-17T13:29:29.245","vulnerabilities":[{"cve":{"id":"CVE-2024-5659","sourceIdentifier":"PSIRT@rockwellautomation.com","published":"2024-06-14T17:15:51.600","lastModified":"2025-03-03T19:37:09.243","vulnStatus":"Analyzed","cveTags":[],"descriptions":[{"lang":"en","value":"Rockwell Automation was made aware of a vulnerability that causes all affected controllers on the same network to result in a major nonrecoverable fault(MNRF/Assert). This vulnerability could be exploited by sending abnormal packets to the mDNS port. If exploited, the availability of the device would be compromised."},{"lang":"es","value":"Rockwell Automation fue informado de una vulnerabilidad que hace que todos los controladores afectados en la misma red produzcan una falla importante no recuperable (MNRF/Assert). Esta vulnerabilidad podría explotarse enviando paquetes anormales al puerto mDNS. Si se explota, la disponibilidad del dispositivo se vería comprometida."}],"metrics":{"cvssMetricV40":[{"source":"PSIRT@rockwellautomation.com","type":"Secondary","cvssData":{"version":"4.0","vectorString":"CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":8.3,"baseSeverity":"HIGH","attackVector":"ADJACENT","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"NONE","userInteraction":"NONE","vulnConfidentialityImpact":"NONE","vulnIntegrityImpact":"NONE","vulnAvailabilityImpact":"HIGH","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","subAvailabilityImpact":"HIGH","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}}],"cvssMetricV31":[{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H","baseScore":6.5,"baseSeverity":"MEDIUM","attackVector":"ADJACENT_NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"NONE","integrityImpact":"NONE","availabilityImpact":"HIGH"},"exploitabilityScore":2.8,"impactScore":3.6}]},"weaknesses":[{"source":"PSIRT@rockwellautomation.com","type":"Secondary","description":[{"lang":"en","value":"CWE-670"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-670"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:rockwellautomation:controllogix_5580_firmware:34.011:*:*:*:*:*:*:*","matchCriteriaId":"02F74A5B-BE74-4F8B-B8D3-D1D48A6C5CA0"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:rockwellautomation:controllogix_5580:-:*:*:*:*:*:*:*","matchCriteriaId":"51BB883B-B863-4D57-B1C0-FC7B3EBD1EA0"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:rockwellautomation:guardlogix_5580_firmware:34.011:*:*:*:*:*:*:*","matchCriteriaId":"D8B88DDE-9002-4EE8-BAA8-73330CB0BE50"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:rockwellautomation:guardlogix_5580:-:*:*:*:*:*:*:*","matchCriteriaId":"006B7683-9FDF-4748-BA28-2EA22613E092"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:rockwellautomation:1756-en4_firmware:4.001:*:*:*:*:*:*:*","matchCriteriaId":"3B050175-3923-4B1E-AE98-53AF028EE8AA"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:rockwellautomation:1756-en4:-:*:*:*:*:*:*:*","matchCriteriaId":"6935642C-4CBF-4B4F-A509-561B3E39A66B"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:rockwellautomation:compactlogix_5380_firmware:34.011:*:*:*:*:*:*:*","matchCriteriaId":"EC388DFC-DA67-44B6-AE97-731B33F38992"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:rockwellautomation:compactlogix_5380:-:*:*:*:*:*:*:*","matchCriteriaId":"EDD040ED-B44C-47D0-B4D4-729C378C4F68"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:rockwellautomation:compact_guardlogix_5380_firmware:34.011:*:*:*:*:*:*:*","matchCriteriaId":"01EB5C9E-A10F-4D53-AF3D-38055F966BD6"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:rockwellautomation:compact_guardlogix_5380:-:*:*:*:*:*:*:*","matchCriteriaId":"62414E65-73C7-4172-B7BF-F40A66AFBB90"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:rockwellautomation:compactlogix_5480_firmware:34.011:*:*:*:*:*:*:*","matchCriteriaId":"A913AF0F-DA08-4FE9-9E94-AA1D6227981B"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:rockwellautomation:compactlogix_5480:-:*:*:*:*:*:*:*","matchCriteriaId":"80F4F5BE-07DF-402A-BF98-34FBA6A11968"}]}]}],"references":[{"url":"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1673.html","source":"PSIRT@rockwellautomation.com","tags":["Vendor Advisory"]},{"url":"https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1673.html","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Vendor Advisory"]}]}}]}