{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-25T04:36:47.780","vulnerabilities":[{"cve":{"id":"CVE-2024-5558","sourceIdentifier":"cybersecurity@se.com","published":"2024-06-12T17:15:52.160","lastModified":"2024-11-21T09:47:55.700","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"CWE-367: Time-of-check Time-of-use (TOCTOU) Race Condition vulnerability exists that could\ncause escalation of privileges when an attacker abuses a limited admin account."},{"lang":"es","value":"CWE-367: Existe una vulnerabilidad de condición de ejecución de tiempo de verificación y tiempo de uso (TOCTOU) que podría provocar una escalada de privilegios cuando un atacante abusa de una cuenta de administrador limitada."}],"metrics":{"cvssMetricV31":[{"source":"cybersecurity@se.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H","baseScore":6.4,"baseSeverity":"MEDIUM","attackVector":"LOCAL","attackComplexity":"HIGH","privilegesRequired":"HIGH","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":0.5,"impactScore":5.9},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H","baseScore":6.4,"baseSeverity":"MEDIUM","attackVector":"LOCAL","attackComplexity":"HIGH","privilegesRequired":"HIGH","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":0.5,"impactScore":5.9}]},"weaknesses":[{"source":"cybersecurity@se.com","type":"Secondary","description":[{"lang":"en","value":"CWE-367"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:spacelogic_as-b_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"6.0.1","matchCriteriaId":"5BD47138-7C8F-4D8B-A669-74395596363D"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:spacelogic_as-b:-:*:*:*:*:*:*:*","matchCriteriaId":"A50B62A0-A6FB-4AB4-94A0-D054C5ADB015"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:schneider-electric:spacelogic_as-p_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"6.0.1","matchCriteriaId":"CA1ABCFA-8D7D-4288-AA9F-FF1B177DBB4E"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:schneider-electric:spacelogic_as-p:-:*:*:*:*:*:*:*","matchCriteriaId":"E516910C-FC39-46FA-82A5-0BF3546FDF33"}]}]}],"references":[{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-163-04.pdf","source":"cybersecurity@se.com","tags":["Patch","Vendor Advisory"]},{"url":"https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-163-04.pdf","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Patch","Vendor Advisory"]}]}}]}