{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-06-02T10:51:09.065","vulnerabilities":[{"cve":{"id":"CVE-2024-54038","sourceIdentifier":"psirt@adobe.com","published":"2024-12-10T21:15:21.210","lastModified":"2025-01-15T17:39:33.503","vulnStatus":"Analyzed","cveTags":[],"descriptions":[{"lang":"en","value":"Adobe Connect versions 12.6, 11.4.7 and earlier are affected by an Improper Access Control vulnerability that could result in a Security feature bypass. A low-privileged attacker could leverage this vulnerability to bypass security measures and have a low impact on confidentiality. Exploitation of this issue does not require user interaction."},{"lang":"es","value":"Las versiones 12.6, 11.4.7 y anteriores de Adobe Connect se ven afectadas por una vulnerabilidad de control de acceso inadecuado que podría provocar la omisión de una función de seguridad. Un atacante podría aprovechar esta vulnerabilidad para eludir las medidas de seguridad y obtener acceso no autorizado. La explotación de este problema no requiere la interacción del usuario."}],"metrics":{"cvssMetricV31":[{"source":"psirt@adobe.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N","baseScore":4.3,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"LOW","integrityImpact":"NONE","availabilityImpact":"NONE"},"exploitabilityScore":2.8,"impactScore":1.4},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N","baseScore":4.3,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"LOW","integrityImpact":"NONE","availabilityImpact":"NONE"},"exploitabilityScore":2.8,"impactScore":1.4}]},"weaknesses":[{"source":"psirt@adobe.com","type":"Secondary","description":[{"lang":"en","value":"CWE-284"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"NVD-CWE-noinfo"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:adobe:connect:*:*:*:*:*:*:*:*","versionEndExcluding":"11.4.9","matchCriteriaId":"599EEA89-BDA1-4FF2-9B78-103DDDD1E262"},{"vulnerable":true,"criteria":"cpe:2.3:a:adobe:connect:*:*:*:*:*:*:*:*","versionStartIncluding":"12.0","versionEndExcluding":"12.7","matchCriteriaId":"E877A861-6761-4E6E-8589-34C30346DCEE"}]}]}],"references":[{"url":"https://helpx.adobe.com/security/products/connect/apsb24-99.html","source":"psirt@adobe.com","tags":["Vendor Advisory"]}]}}]}