{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-19T12:12:21.247","vulnerabilities":[{"cve":{"id":"CVE-2024-53649","sourceIdentifier":"productcert@siemens.com","published":"2025-01-14T11:15:16.820","lastModified":"2026-04-15T00:35:42.020","vulnStatus":"Deferred","cveTags":[],"descriptions":[{"lang":"en","value":"A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V9.80), SIPROTEC 5 6MD85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 6MD86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 6MD89 (CP300) (All versions >= V7.80 < V9.68), SIPROTEC 5 6MU85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7KE85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SA82 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7SA82 (CP150) (All versions < V9.80), SIPROTEC 5 7SA86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SA87 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SD82 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7SD82 (CP150) (All versions < V9.80), SIPROTEC 5 7SD86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SD87 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SJ81 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7SJ81 (CP150) (All versions < V9.80), SIPROTEC 5 7SJ82 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7SJ82 (CP150) (All versions < V9.80), SIPROTEC 5 7SJ85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SJ86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SK82 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7SK82 (CP150) (All versions < V9.80), SIPROTEC 5 7SK85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SL82 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7SL82 (CP150) (All versions < V9.80), SIPROTEC 5 7SL86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SL87 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7SS85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7ST85 (CP300) (All versions < V9.68), SIPROTEC 5 7ST86 (CP300) (All versions < V9.80), SIPROTEC 5 7SX82 (CP150) (All versions < V9.80), SIPROTEC 5 7SX85 (CP300) (All versions < V9.80), SIPROTEC 5 7SY82 (CP150) (All versions < V9.80), SIPROTEC 5 7UM85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7UT82 (CP100) (All versions >= V7.80 < V8.90), SIPROTEC 5 7UT82 (CP150) (All versions < V9.80), SIPROTEC 5 7UT85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7UT86 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7UT87 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7VE85 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7VK87 (CP300) (All versions >= V7.80 < V9.80), SIPROTEC 5 7VU85 (CP300) (All versions < V9.80), SIPROTEC 5 Compact 7SX800 (CP050) (All versions < V9.80). Affected devices do not properly limit the path accessible via their webserver.  This could allow an authenticated remote attacker to read arbitrary files from the filesystem of affected devices."},{"lang":"es","value":"Se ha identificado una vulnerabilidad en SIPROTEC 5 6MD84 (CP300) (Todas las versiones &lt; V9.80), SIPROTEC 5 6MD85 (CP300) (Todas las versiones &gt;= V7.80 &lt; V9.80), SIPROTEC 5 6MD86 (CP300) (Todas las versiones &gt;= V7.80 &lt; V9.80), SIPROTEC 5 6MD89 (CP300) (Todas las versiones &gt;= V7.80), SIPROTEC 5 6MU85 (CP300) (Todas las versiones &gt;= V7.80 &lt; V9.80), SIPROTEC 5 7KE85 (CP300) (Todas las versiones &gt;= V7.80 &lt; V9.80), SIPROTEC 5 7SA82 (CP100) (Todas las versiones &gt;= V7.80), SIPROTEC 5 7SA82 (CP150) (Todas las versiones &lt; V9.80), SIPROTEC 5 7SA86 (CP300) (Todas las versiones &gt;= V7.80 &lt; V9.80), SIPROTEC 5 7SA87 (CP300) (Todas las versiones &gt;= V7.80 &lt; V9.80), SIPROTEC 5 7SD82 (CP100) (Todas las versiones &gt;= V7.80), SIPROTEC 5 7SD82 (CP150) (Todas las versiones &lt; V9.80), SIPROTEC 5 7SD86 (CP300) (Todas las versiones &gt;= V7.80 &lt; V9.80), SIPROTEC 5 7SD87 (CP300) (Todas las versiones &gt;= V7.80 &lt; V9.80), SIPROTEC 5 7SJ81 (CP100) (Todas las versiones &gt;= V7.80), SIPROTEC 5 7SJ81 (CP150) (Todas las versiones &lt; V9.80), SIPROTEC 5 7SJ82 (CP100) (Todas las versiones &gt;= V7.80), SIPROTEC 5 7SJ82 (CP150) (Todas las versiones &lt; V9.80), SIPROTEC 5 7SJ85 (CP300) (Todas las versiones &gt;= V7.80 &lt; V9.80), SIPROTEC 5 7SJ86 (CP300) (Todas las versiones &gt;= V7.80 &lt; V9.80), SIPROTEC 5 7SK82 (CP100) (Todas las versiones &gt;= V7.80), SIPROTEC 5 7SK82 (CP150) (Todas las versiones &lt; V9.80), SIPROTEC 5 7SK85 (CP300) (Todas las versiones &gt;= V7.80 &lt; V9.80), SIPROTEC 5 7SL82 (CP100) (Todas las versiones &gt;= V7.80), SIPROTEC 5 7SL82 (CP150) (Todas las versiones &lt; V9.80), SIPROTEC 5 7SL86 (CP300) (Todas las versiones &gt;= V7.80 &lt; V9.80), SIPROTEC 5 7SL87 (CP300) (Todas las versiones &gt;= V7.80 &lt; V9.80), SIPROTEC 5 7SS85 (CP300) (Todas las versiones &gt;= V7.80 &lt; V9.80), SIPROTEC 5 7ST85 (CP300) (Todas las versiones), SIPROTEC 5 7ST86 (CP300) (Todas las versiones &lt; V9.80), SIPROTEC 5 7SX82 (CP150) (Todas las versiones &lt; V9.80), SIPROTEC 5 7SX85 (CP300) (Todas las versiones &lt; V9.80), SIPROTEC 5 7SY82 (CP150) (Todas las versiones &lt; V9.80), SIPROTEC 5 7UM85 (CP300) (Todas las versiones &gt;= V7.80 &lt; V9.80), SIPROTEC 5 7UT82 (CP100) (Todas las versiones &gt;= V7.80), SIPROTEC 5 7UT82 (CP150) (Todas las versiones &lt; V9.80), SIPROTEC 5 7UT85 (CP300) (Todas las versiones &gt;= V7.80 &lt; V9.80), SIPROTEC 5 7UT86 (CP300) (Todas las versiones &gt;= V7.80 &lt; V9.80), SIPROTEC 5 7UT87 (CP300) (Todas las versiones &gt;= V7.80 &lt; V9.80), SIPROTEC 5 7VE85 (CP300) (Todas las versiones &gt;= V7.80 &lt; V9.80), SIPROTEC 5 7VK87 (CP300) (Todas las versiones &gt;= V7.80 &lt; V9.80), SIPROTEC 5 7VU85 (CP300) (todas las versiones anteriores a V9.80), SIPROTEC 5 Compact 7SX800 (CP050) (todas las versiones anteriores a V9.80). Los dispositivos afectados no limitan adecuadamente la ruta a la que se puede acceder a través de su servidor web. Esto podría permitir que un atacante remoto autenticado lea archivos arbitrarios del sistema de archivos de los dispositivos afectados."}],"metrics":{"cvssMetricV40":[{"source":"productcert@siemens.com","type":"Secondary","cvssData":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":7.1,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"LOW","userInteraction":"NONE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"NONE","vulnAvailabilityImpact":"NONE","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}}],"cvssMetricV31":[{"source":"productcert@siemens.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N","baseScore":6.5,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"NONE","availabilityImpact":"NONE"},"exploitabilityScore":2.8,"impactScore":3.6}]},"weaknesses":[{"source":"productcert@siemens.com","type":"Secondary","description":[{"lang":"en","value":"CWE-552"}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-194557.html","source":"productcert@siemens.com"}]}}]}