{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-06-09T12:47:52.728","vulnerabilities":[{"cve":{"id":"CVE-2024-50562","sourceIdentifier":"psirt@fortinet.com","published":"2025-06-10T17:19:25.360","lastModified":"2026-06-09T10:16:32.237","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"An Insufficient Session Expiration vulnerability [CWE-613] in FortiOS SSL-VPN version 7.6.0, version 7.4.6 and below, version 7.2.10 and below, 7.0 all versions, 6.4 all versions may allow an attacker in possession of a cookie used to log in the SSL-VPN portal to log in again, although the session has expired or was logged out."},{"lang":"es","value":"Una vulnerabilidad de expiración de sesión insuficiente [CWE-613] en FortiOS SSL-VPN versión 7.6.0, versión 7.4.6 y anteriores, versión 7.2.10 y anteriores, 7.0 todas las versiones, 6.4 todas las versiones puede permitir que un atacante en posesión de una cookie utilizada para iniciar sesión en el portal SSL-VPN inicie sesión nuevamente, aunque la sesión haya expirado o se haya cerrado la sesión."}],"metrics":{"cvssMetricV31":[{"source":"psirt@fortinet.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:N","baseScore":4.8,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"HIGH","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"LOW","integrityImpact":"LOW","availabilityImpact":"NONE"},"exploitabilityScore":2.2,"impactScore":2.5}]},"weaknesses":[{"source":"psirt@fortinet.com","type":"Secondary","description":[{"lang":"en","value":"CWE-613"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:fortinet:fortisase:24.4.60:*:*:*:-:*:*:*","matchCriteriaId":"2F69F805-E87B-4711-8B8F-ED4581534E8C"},{"vulnerable":true,"criteria":"cpe:2.3:o:fortinet:fortios:*:*:*:*:*:*:*:*","versionStartIncluding":"6.4.0","versionEndExcluding":"7.2.11","matchCriteriaId":"753664B2-3AE8-499A-9C8A-B7D928439697"},{"vulnerable":true,"criteria":"cpe:2.3:o:fortinet:fortios:*:*:*:*:*:*:*:*","versionStartIncluding":"7.4.0","versionEndExcluding":"7.4.8","matchCriteriaId":"26515743-5A9A-4885-A08E-535E4ABE0153"},{"vulnerable":true,"criteria":"cpe:2.3:o:fortinet:fortios:7.6.0:*:*:*:*:*:*:*","matchCriteriaId":"44CE8EE3-D64A-49C8-87D7-C18B302F864A"}]}]}],"references":[{"url":"https://fortiguard.fortinet.com/psirt/FG-IR-24-339","source":"psirt@fortinet.com","tags":["Vendor Advisory"]},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-864900.html","source":"0b142b55-0307-4c5a-b3c9-f314f3fb7c5e"}]}}]}