{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-05-11T20:46:58.799","vulnerabilities":[{"cve":{"id":"CVE-2024-46890","sourceIdentifier":"productcert@siemens.com","published":"2024-11-12T13:15:09.463","lastModified":"2024-11-13T23:12:39.993","vulnStatus":"Analyzed","cveTags":[],"descriptions":[{"lang":"en","value":"A vulnerability has been identified in SINEC INS (All versions < V1.0 SP2 Update 3). The affected application does not properly validate input sent to specific endpoints of its web API. This could allow an authenticated remote attacker with high privileges on the application to execute arbitrary code on the underlying OS."},{"lang":"es","value":"Se ha identificado una vulnerabilidad en SINEC INS (todas las versiones &lt; V1.0 SP2 Update 3). La aplicación afectada no valida correctamente la entrada enviada a endpoints específicos de su API web. Esto podría permitir que un atacante remoto autenticado con privilegios elevados en la aplicación ejecute código arbitrario en el sistema operativo subyacente."}],"metrics":{"cvssMetricV40":[{"source":"productcert@siemens.com","type":"Secondary","cvssData":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":9.4,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"HIGH","userInteraction":"NONE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnAvailabilityImpact":"HIGH","subConfidentialityImpact":"HIGH","subIntegrityImpact":"HIGH","subAvailabilityImpact":"HIGH","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}}],"cvssMetricV31":[{"source":"productcert@siemens.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H","baseScore":9.1,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"HIGH","userInteraction":"NONE","scope":"CHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.3,"impactScore":6.0}]},"weaknesses":[{"source":"productcert@siemens.com","type":"Secondary","description":[{"lang":"en","value":"CWE-78"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:sinec_ins:*:*:*:*:*:*:*:*","versionEndExcluding":"1.0","matchCriteriaId":"C89891C1-DFD7-4E1F-80A9-7485D86A15B5"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:sinec_ins:1.0:-:*:*:*:*:*:*","matchCriteriaId":"4664B195-AF14-4834-82B3-0B2C98020EB6"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:sinec_ins:1.0:sp1:*:*:*:*:*:*","matchCriteriaId":"75BC588E-CDF0-404E-AD61-02093A1DF343"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:sinec_ins:1.0:sp2:*:*:*:*:*:*","matchCriteriaId":"A334F7B4-7283-4453-BAED-D2E01B7F8A6E"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:sinec_ins:1.0:sp2_update_1:*:*:*:*:*:*","matchCriteriaId":"A6BEA71C-CA81-4B5D-A688-2B21E62DC351"},{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:sinec_ins:1.0:sp2_update_2:*:*:*:*:*:*","matchCriteriaId":"6B405F22-5517-49F5-A7CA-1E50D58DFC75"}]}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-915275.html","source":"productcert@siemens.com","tags":["Vendor Advisory"]}]}}]}