{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-17T09:38:06.727","vulnerabilities":[{"cve":{"id":"CVE-2024-43653","sourceIdentifier":"csirt@divd.nl","published":"2025-01-09T08:15:27.950","lastModified":"2026-04-15T00:35:42.020","vulnStatus":"Deferred","cveTags":[],"descriptions":[{"lang":"en","value":"Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability  allows OS Command Injection as root\nThis issue affects Iocharger firmware for AC model chargers before version 24120701.\n\nLikelihood: Moderate – The <redacted> binary does not seem to be used by the web interface, so it might be more difficult to find. It seems to be largely the same binary as used by the Iocharger Pedestal charging station, however. The attacker will also need a (low privilege) account to gain access to the <redacted> binary, or convince a user with such access to execute a crafted HTTP request.\n\nImpact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and delete\nfiles and services.\n\nCVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y)."},{"lang":"es","value":"Vulnerabilidad de neutralización incorrecta de elementos especiales utilizados en un comando ('Inyección de comando') permite la inyección de comandos del sistema operativo como root Este problema afecta al firmware de Iocharger para cargadores modelo AC anteriores a la versión 24120701. Probabilidad: moderada: el binario  no parece ser utilizado por la interfaz web, por lo que podría ser más difícil de encontrar. Sin embargo, parece ser en gran medida el mismo binario que utiliza la estación de carga Pedestal de Iocharger. El atacante también necesitará una cuenta (con privilegios bajos) para obtener acceso al binario  o convencer a un usuario con dicho acceso para que ejecute una solicitud HTTP manipulada. Impacto: crítico: el atacante tiene control total sobre la estación de carga como usuario superusuario y puede agregar, modificar y eliminar archivos y servicios de forma arbitraria. Aclaración de CVSS: cualquier interfaz de red que sirva a la interfaz de usuario web es vulnerable (AV:N) y no hay medidas de seguridad adicionales para eludir (AC:L), ni el ataque requiere condiciones previas existentes (AT:N). El ataque está autenticado, pero el nivel de autenticación no importa (PR:L), ni se requiere interacción del usuario (UI:N). El ataque lleva a una vulnerabilidad total (VC:H/VI:H/VA:H), y los dispositivos afectados pueden usarse para ingresar a redes que potencialmente no deberían ser accesibles (SC:L/SI:L/SA:H). Debido a que se trata de un cargador de vehículos eléctricos que gestiona una cantidad significativa de energía, existe un posible impacto en la seguridad (S:P). Este ataque puede automatizarse (AU:Y)."}],"metrics":{"cvssMetricV40":[{"source":"csirt@divd.nl","type":"Secondary","cvssData":{"version":"4.0","vectorString":"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:L/SI:L/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:P/AU:Y/R:X/V:X/RE:X/U:X","baseScore":9.3,"baseSeverity":"CRITICAL","attackVector":"NETWORK","attackComplexity":"LOW","attackRequirements":"NONE","privilegesRequired":"LOW","userInteraction":"NONE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnAvailabilityImpact":"HIGH","subConfidentialityImpact":"LOW","subIntegrityImpact":"LOW","subAvailabilityImpact":"HIGH","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"PRESENT","Automatable":"YES","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}}],"cvssMetricV31":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H","baseScore":8.8,"baseSeverity":"HIGH","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"LOW","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":2.8,"impactScore":5.9}]},"weaknesses":[{"source":"csirt@divd.nl","type":"Secondary","description":[{"lang":"en","value":"CWE-78"},{"lang":"en","value":"CWE-250"}]}],"references":[{"url":"https://csirt.divd.nl/CVE-2024-43653/","source":"csirt@divd.nl"},{"url":"https://csirt.divd.nl/DIVD-2024-00035/","source":"csirt@divd.nl"},{"url":"https://iocharger.com","source":"csirt@divd.nl"}]}}]}