{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-06-12T11:38:01.186","vulnerabilities":[{"cve":{"id":"CVE-2024-42424","sourceIdentifier":"security_alert@emc.com","published":"2024-09-10T08:15:02.487","lastModified":"2024-12-20T14:41:45.593","vulnStatus":"Analyzed","cveTags":[],"descriptions":[{"lang":"en","value":"Dell Precision Rack, 14G Intel BIOS versions prior to 2.22.2, contains an Improper Input Validation vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Information disclosure."},{"lang":"es","value":"Las versiones de BIOS de Intel para Dell Precision Rack 14G anteriores a la 2.22.2 contienen una vulnerabilidad de validación de entrada incorrecta. Un atacante con privilegios elevados y acceso local podría aprovechar esta vulnerabilidad, lo que provocaría la divulgación de información."}],"metrics":{"cvssMetricV31":[{"source":"security_alert@emc.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:C/C:H/I:N/A:N","baseScore":5.3,"baseSeverity":"MEDIUM","attackVector":"LOCAL","attackComplexity":"HIGH","privilegesRequired":"HIGH","userInteraction":"NONE","scope":"CHANGED","confidentialityImpact":"HIGH","integrityImpact":"NONE","availabilityImpact":"NONE"},"exploitabilityScore":0.8,"impactScore":4.0},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N","baseScore":6.0,"baseSeverity":"MEDIUM","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"HIGH","userInteraction":"NONE","scope":"CHANGED","confidentialityImpact":"HIGH","integrityImpact":"NONE","availabilityImpact":"NONE"},"exploitabilityScore":1.5,"impactScore":4.0}]},"weaknesses":[{"source":"security_alert@emc.com","type":"Secondary","description":[{"lang":"en","value":"CWE-20"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"NVD-CWE-noinfo"}]}],"configurations":[{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:dell:precision_7920_rack_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"2.22.1","matchCriteriaId":"61F7B9AB-E6B6-4B3E-871C-6653922AA440"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:dell:precision_7920_rack:-:*:*:*:*:*:*:*","matchCriteriaId":"0C2430E8-4607-4255-AFD2-99CAEE7BFD73"}]}]},{"operator":"AND","nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:o:dell:7920_xl_rack_firmware:*:*:*:*:*:*:*:*","versionEndExcluding":"2.22.1","matchCriteriaId":"FE43ACC5-1E0E-4B43-925F-E0E7C6D5D53E"}]},{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":false,"criteria":"cpe:2.3:h:dell:7920_xl_rack:-:*:*:*:*:*:*:*","matchCriteriaId":"19361B06-2F31-49BB-A3E6-5A5AC972AE01"}]}]}],"references":[{"url":"https://www.dell.com/support/kbdoc/en-us/000227014/dsa-2024-327","source":"security_alert@emc.com","tags":["Vendor Advisory"]}]}}]}