{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-05-01T12:42:24.060","vulnerabilities":[{"cve":{"id":"CVE-2024-41986","sourceIdentifier":"productcert@siemens.com","published":"2025-08-12T12:15:33.157","lastModified":"2025-10-22T18:33:23.943","vulnStatus":"Analyzed","cveTags":[],"descriptions":[{"lang":"en","value":"A vulnerability has been identified in SmartClient modules Opcenter QL Home (SC) (All versions >= V13.2 < V2506), SOA Audit (All versions >= V13.2 < V2506), SOA Cockpit (All versions >= V13.2 < V2506). The affected application support insecure TLS 1.0 and 1.1 protocol. An attacker could achieve a man-in-the-middle attack and compromise confidentiality and integrity of data."},{"lang":"es","value":"Se ha identificado una vulnerabilidad en los módulos SmartClient Opcenter QL Home (SC) (todas las versiones &gt;= V13.2 &lt; V2506), SOA Audit (todas las versiones &gt;= V13.2 &lt; V2506) y SOA Cockpit (todas las versiones &gt;= V13.2 &lt; V2506). La aplicación afectada admite el protocolo TLS 1.0 y 1.1 inseguro. Un atacante podría realizar un ataque de intermediario y comprometer la confidencialidad e integridad de los datos."}],"metrics":{"cvssMetricV40":[{"source":"productcert@siemens.com","type":"Secondary","cvssData":{"version":"4.0","vectorString":"CVSS:4.0/AV:A/AC:H/AT:P/PR:N/UI:N/VC:H/VI:L/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":6.1,"baseSeverity":"MEDIUM","attackVector":"ADJACENT","attackComplexity":"HIGH","attackRequirements":"PRESENT","privilegesRequired":"NONE","userInteraction":"NONE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"LOW","vulnAvailabilityImpact":"LOW","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}}],"cvssMetricV31":[{"source":"productcert@siemens.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:L/A:L","baseScore":6.4,"baseSeverity":"MEDIUM","attackVector":"ADJACENT_NETWORK","attackComplexity":"HIGH","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"LOW","availabilityImpact":"LOW"},"exploitabilityScore":1.6,"impactScore":4.7},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N","baseScore":6.8,"baseSeverity":"MEDIUM","attackVector":"ADJACENT_NETWORK","attackComplexity":"HIGH","privilegesRequired":"NONE","userInteraction":"NONE","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"NONE"},"exploitabilityScore":1.6,"impactScore":5.2}]},"weaknesses":[{"source":"productcert@siemens.com","type":"Secondary","description":[{"lang":"en","value":"CWE-327"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:siemens:opcenter_quality:13.2:*:*:*:*:*:*:*","matchCriteriaId":"238C890D-8EBF-4378-B887-89AED294F983"}]}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-382999.html","source":"productcert@siemens.com","tags":["Vendor Advisory"]}]}}]}