{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-17T16:53:50.104","vulnerabilities":[{"cve":{"id":"CVE-2024-3982","sourceIdentifier":"cybersecurity@hitachienergy.com","published":"2024-08-27T13:15:05.557","lastModified":"2024-10-30T15:32:23.680","vulnStatus":"Analyzed","cveTags":[],"descriptions":[{"lang":"en","value":"An attacker with local access to machine where MicroSCADA X\nSYS600 is installed, could enable the session logging supporting the product and try to exploit a session hijacking of an already established session. By default, the session logging level\nis not enabled and only users with administrator rights can enable it."},{"lang":"es","value":"Un atacante con acceso local a la máquina donde está instalado MicroSCADA X SYS600, podría habilitar el registro de sesiones que soporta el producto e intentar explotar un secuestro de sesión de una sesión ya establecida. De forma predeterminada, el nivel de registro de sesión no está habilitado y solo los usuarios con derechos de administrador pueden habilitarlo."}],"metrics":{"cvssMetricV31":[{"source":"cybersecurity@hitachienergy.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H","baseScore":8.2,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"HIGH","userInteraction":"NONE","scope":"CHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.5,"impactScore":6.0},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H","baseScore":8.2,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"HIGH","userInteraction":"NONE","scope":"CHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.5,"impactScore":6.0}]},"weaknesses":[{"source":"cybersecurity@hitachienergy.com","type":"Secondary","description":[{"lang":"en","value":"CWE-294"}]},{"source":"nvd@nist.gov","type":"Primary","description":[{"lang":"en","value":"CWE-294"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:hitachienergy:microscada_x_sys600:*:*:*:*:*:*:*:*","versionStartIncluding":"10.0","versionEndExcluding":"10.6","matchCriteriaId":"AEAAFA90-ACFF-47E2-A23D-728912D74B99"}]}]}],"references":[{"url":"https://publisher.hitachienergy.com/preview?DocumentID=8DBD000160&LanguageCode=en&DocumentPartId=&Action=Launch","source":"cybersecurity@hitachienergy.com","tags":["Vendor Advisory"]}]}}]}