{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-07-04T20:24:51.091","vulnerabilities":[{"cve":{"id":"CVE-2024-38436","sourceIdentifier":"cna@cyber.gov.il","published":"2024-07-21T08:15:05.997","lastModified":"2026-06-17T07:40:16.620","vulnStatus":"Modified","cveTags":[],"descriptions":[{"lang":"en","value":"Commugen SOX 365 – CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')"},{"lang":"es","value":" Commugen SOX 365 – CWE-79: neutralización incorrecta de la entrada durante la generación de páginas web ('Cross Site Scripting')"}],"affected":[{"source":"cna@cyber.gov.il","affectedData":[{"vendor":"Commugen","product":"SOX 365","defaultStatus":"unaffected","versions":[{"version":"All versions","lessThan":"Upgrade to version 3.0.2405.18500","versionType":"custom","status":"affected"}]}]}],"metrics":{"cvssMetricV31":[{"source":"cna@cyber.gov.il","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N","baseScore":6.1,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"CHANGED","confidentialityImpact":"LOW","integrityImpact":"LOW","availabilityImpact":"NONE"},"exploitabilityScore":2.8,"impactScore":2.7},{"source":"nvd@nist.gov","type":"Primary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N","baseScore":6.1,"baseSeverity":"MEDIUM","attackVector":"NETWORK","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"CHANGED","confidentialityImpact":"LOW","integrityImpact":"LOW","availabilityImpact":"NONE"},"exploitabilityScore":2.8,"impactScore":2.7}],"ssvcV203":[{"source":"134c704f-9b21-4f2e-91b3-4a467353bcc0","ssvcData":{"timestamp":"2024-07-22T15:51:38.976191Z","id":"CVE-2024-38436","options":[{"exploitation":"none"},{"automatable":"no"},{"technicalImpact":"partial"}],"role":"CISA Coordinator","version":"2.0.3"}}]},"weaknesses":[{"source":"cna@cyber.gov.il","type":"Secondary","description":[{"lang":"en","value":"CWE-79"}]}],"configurations":[{"nodes":[{"operator":"OR","negate":false,"cpeMatch":[{"vulnerable":true,"criteria":"cpe:2.3:a:commugen:sox_365:*:*:*:*:*:*:*:*","versionEndExcluding":"3.0.2405.18500","matchCriteriaId":"D146A79E-0066-429F-A6F3-CDAF42199F9D"}]}]}],"references":[{"url":"https://www.gov.il/en/Departments/faq/cve_advisories","source":"cna@cyber.gov.il","tags":["Third Party Advisory"]},{"url":"https://www.gov.il/en/Departments/faq/cve_advisories","source":"af854a3a-2127-422b-91ae-364da2661108","tags":["Third Party Advisory"]}]}}]}