{"resultsPerPage":1,"startIndex":0,"totalResults":1,"format":"NVD_CVE","version":"2.0","timestamp":"2026-04-17T15:41:48.909","vulnerabilities":[{"cve":{"id":"CVE-2024-37997","sourceIdentifier":"productcert@siemens.com","published":"2024-07-09T12:15:15.280","lastModified":"2026-04-15T00:35:42.020","vulnStatus":"Deferred","cveTags":[],"descriptions":[{"lang":"en","value":"A vulnerability has been identified in JT Open (All versions < V11.5), JT2Go (All versions < V2406.0003), PLM XML SDK (All versions < V7.1.0.014), Teamcenter Visualization V14.2 (All versions < V14.2.0.13), Teamcenter Visualization V14.3 (All versions < V14.3.0.11), Teamcenter Visualization V2312 (All versions < V2312.0008), Teamcenter Visualization V2406 (All versions < V2406.0003). The affected applications contain a stack based overflow vulnerability while parsing specially crafted XML files. This could allow an attacker to execute code in the context of the current process."},{"lang":"es","value":"Se ha identificado una vulnerabilidad en JT Open (todas las versiones &lt; V11.5), PLM XML SDK (todas las versiones &lt; V7.1.0.014). Las aplicaciones afectadas contienen una vulnerabilidad de desbordamiento de búfer en la región stack de la memoria al analizar archivos XML especialmente manipulados. Esto podría permitir a un atacante ejecutar código en el contexto del proceso actual."}],"metrics":{"cvssMetricV40":[{"source":"productcert@siemens.com","type":"Secondary","cvssData":{"version":"4.0","vectorString":"CVSS:4.0/AV:L/AC:H/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X","baseScore":7.3,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"HIGH","attackRequirements":"NONE","privilegesRequired":"NONE","userInteraction":"PASSIVE","vulnConfidentialityImpact":"HIGH","vulnIntegrityImpact":"HIGH","vulnAvailabilityImpact":"HIGH","subConfidentialityImpact":"NONE","subIntegrityImpact":"NONE","subAvailabilityImpact":"NONE","exploitMaturity":"NOT_DEFINED","confidentialityRequirement":"NOT_DEFINED","integrityRequirement":"NOT_DEFINED","availabilityRequirement":"NOT_DEFINED","modifiedAttackVector":"NOT_DEFINED","modifiedAttackComplexity":"NOT_DEFINED","modifiedAttackRequirements":"NOT_DEFINED","modifiedPrivilegesRequired":"NOT_DEFINED","modifiedUserInteraction":"NOT_DEFINED","modifiedVulnConfidentialityImpact":"NOT_DEFINED","modifiedVulnIntegrityImpact":"NOT_DEFINED","modifiedVulnAvailabilityImpact":"NOT_DEFINED","modifiedSubConfidentialityImpact":"NOT_DEFINED","modifiedSubIntegrityImpact":"NOT_DEFINED","modifiedSubAvailabilityImpact":"NOT_DEFINED","Safety":"NOT_DEFINED","Automatable":"NOT_DEFINED","Recovery":"NOT_DEFINED","valueDensity":"NOT_DEFINED","vulnerabilityResponseEffort":"NOT_DEFINED","providerUrgency":"NOT_DEFINED"}}],"cvssMetricV31":[{"source":"productcert@siemens.com","type":"Secondary","cvssData":{"version":"3.1","vectorString":"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H","baseScore":7.8,"baseSeverity":"HIGH","attackVector":"LOCAL","attackComplexity":"LOW","privilegesRequired":"NONE","userInteraction":"REQUIRED","scope":"UNCHANGED","confidentialityImpact":"HIGH","integrityImpact":"HIGH","availabilityImpact":"HIGH"},"exploitabilityScore":1.8,"impactScore":5.9}]},"weaknesses":[{"source":"productcert@siemens.com","type":"Secondary","description":[{"lang":"en","value":"CWE-121"}]}],"references":[{"url":"https://cert-portal.siemens.com/productcert/html/ssa-824889.html","source":"productcert@siemens.com"},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-959281.html","source":"productcert@siemens.com"},{"url":"https://cert-portal.siemens.com/productcert/html/ssa-824889.html","source":"af854a3a-2127-422b-91ae-364da2661108"}]}}]}